# Principles of Rigid Fixation

> Rigid fixation for BDS Oral Surgery covering AO ASIF principles, primary bone healing, Champy ideal lines, miniplates, lag screws and load-sharing plates.

- Canonical URL: https://prepelephant.com/topics/bds/oral-surgery/rigid-fixation-principles
- Exam / course: BDS · Subject: Oral Surgery
- Publisher: PrepElephant (https://prepelephant.com) — Prepared and reviewed by the PrepElephant Academic Review Team
- First published: 2026-10-02
- Last updated: 2026-10-08
- Reference basis: Rowe and Williams Maxillofacial Injuries; Textbook of Oral and Maxillofacial Surgery
- How to cite: "Principles of Rigid Fixation", PrepElephant, https://prepelephant.com/topics/bds/oral-surgery/rigid-fixation-principles

## Direct answer

Rigid internal fixation holds fractured jaw fragments absolutely still, so bone heals by primary union rather than callus. The principle descends from the AO/ASIF group, whose compressed fragments remodel directly without a cartilage and callus stage. In the mandible, Champy's ideal lines place one miniplate on the oblique line at the angle and two plates at the parasymphysis, where torsion acts.

## What you must remember

- **Core definition:** fixation stable enough to allow immediate function and remove interfragmentary micromovement, so osteons cross the gap directly.
- **Healing contrast:** primary healing under absolute stability versus secondary healing through callus, cartilage and remodelling under mobility.
- **AO/ASIF principles:** anatomical reduction, stable fixation, preservation of blood supply through atraumatic technique, and early active function.
- **Champy's ideal lines:** the biomechanically optimal plate paths, with the parasymphysis needing two plates because muscle pull there is torsional.
- **Biomechanical logic:** the mandible has a tension zone along the upper border and a compression zone along the lower border, so a plate on the tension line neutralises distraction.
- **Hardware hierarchy:** 2.0 mm monocortical miniplates are load-sharing and the everyday standard, while 2.4 mm reconstruction plates with bicortical screws are load-bearing for comminuted or atrophic mandibles.
- **Lag screw principle:** the near cortex is overdrilled to a glide hole and the far cortex tapped, so tightening pulls the fragments together.

## Champy's ideal lines, region by region

Each region takes a plate placed on the line that matches its forces. The table sets out the standard placements.

| Region | Plate placement |
|---|---|
| Angle | One miniplate along the external oblique line, the tension zone |
| Body | One plate below the root apices and above the inferior alveolar canal |
| Parasymphysis | Two plates, one near each cortical surface, because torsion acts |
| Ramus | One plate along the posterior border |

A worked case shows the logic: an angle fracture takes one 2.0 mm monocortical miniplate on the oblique line, while a parasymphyseal fracture takes two parallel plates because the symphyseal segment rotates under torsion.

The single plate at the angle sits on the tension line, while two plates at the parasymphysis answer the torsion question, since one plate alone would act as a pivot. Miniplate screws engage one cortex deliberately, protecting the roots and the inferior alveolar nerve, and load-sharing stability suffices while the bony buttress is intact.

## Where students slip

Four traps recur in osteosynthesis answers.

- **Trap:** reciting Champy's lines without their reason. — **Correct:** the examiner wants the biomechanical answer, torsion at the parasymphysis, not a memorised "the textbook says so".
- **Trap:** confusing load-sharing with load-bearing plates. — **Correct:** miniplates share load with intact bone and fail in comminuted or atrophic mandibles, where only a reconstruction plate carries the full functional load.
- **Trap:** explaining primary healing as "no callus because the plate is strong". — **Correct:** absolute stability lets osteons tunnel directly across the contact zone, which is the mark-winning explanation.
- **Trap:** comparing fixation with wiring only for speed. — **Correct:** the real gain over intermaxillary fixation is avoiding the periodontal and hygiene morbidity of prolonged wiring.

## Frequently asked questions

### What is rigid internal fixation of the mandible?

Rigid internal fixation uses plates and screws stable enough to eliminate interfragmentary movement. It allows primary bone healing and immediate jaw function without prolonged intermaxillary fixation.

### What are Champy's ideal lines of osteosynthesis?

Champy's ideal lines are the biomechanically optimal miniplate paths in the mandible. They are one plate on the oblique line at the angle, one below the roots and above the canal in the body, two at the parasymphysis, and a posterior border plate for the ramus.

### Why does primary bone healing occur with rigid fixation?

Absolute stability lets osteons remodel directly across the fracture contact zone without forming callus. Repeated micromovement would tear the early bony bridges, so this healing needs stability.

### What distinguishes load-sharing from load-bearing fixation?

Load-sharing miniplates work with an intact bony buttress to share the load. Load-bearing reconstruction plates carry the entire functional load across comminuted, defective or atrophic mandibles, where no buttress is left to share it.

### How does a lag screw compress a fracture?

The lag screw glides through an overdrilled near cortex and threads only the far cortex. Tightening it pulls the fragments together, producing interfragmentary compression along the fracture line.