## Direct answer

Labour analgesia climbs a ladder from non-pharmacological support through Entonox, a 50:50 mix of nitrous oxide and oxygen self-administered at each contraction, to systemic opioids and regional blockade. Epidural analgesia, the gold standard, combines a low-concentration local anaesthetic with an opioid for pain relief with motor sparing. Pudendal block covers the second stage and perineal repair.

## What you must remember

- **Entonox:** 50 per cent nitrous oxide with 50 per cent oxygen, self-administered at each contraction, with peak effect in 45-60 seconds; nausea and dizziness limit use, and it is safe for the fetus.
- **Pethidine:** 50-100 mg intramuscularly every 4-6 hours with promethazine or cyclizine; it crosses the placenta with a neonatal half-life far longer than maternal, so it is avoided within 2-4 hours of birth, and naloxone 0.01 mg/kg reverses neonatal depression.
- **Epidural regimen:** 0.0625-0.125 per cent bupivacaine (or 0.1-0.2 per cent ropivacaine) with fentanyl 2 micrograms per mL; a test dose of 3 mL of 1.5-2 per cent lignocaine with adrenaline excludes intravascular or intrathecal placement.
- **Epidural complications:** Hypotension (treated with left tilt, intravenous fluids and ephedrine 6 mg boluses), post-dural-puncture headache (epidural blood patch), a higher instrumental delivery rate, dural tap, and rarely local anaesthetic toxicity or catheter migration.
- **Contraindications to regional block:** Coagulopathy or platelets under about 80 x 10^9/L, sepsis at the insertion site, hypovolaemia, maternal refusal and untreated spinal pathology.
- **Pudendal block:** 10 mL of 1 per cent lignocaine just below each ischial spine, an S2-S4 block for perineal analgesia, useful for instrumental delivery and episiotomy repair when regional is unavailable.
- **Non-pharmacological set:** Continuous labour support (a birth companion, as national guidelines permit), breathing, massage, ambulation, TENS for back pain and water immersion in early labour.
- **Paracervical block:** Relieves first-stage pain but causes fetal bradycardia and is now rarely used, a favourite "which is not used" option.

## Choosing the method for one woman

A 24-year-old primigravida at 4 cm asks for relief, and each step escalates only if the last one fails.

1. **Non-drug start:** Her mother acts as birth companion, with an upright position, breathing and Entonox at each contraction.
2. **Pethidine option:** At 5 cm she is still distressed, so pethidine 100 mg intramuscularly with promethazine blunts pain for three hours. It risks a drowsy baby if she delivers quickly, so naloxone stands by.
3. **Epidural set-up:** She prefers an epidural, so crystalloid preload, left tilt and a catheter at L3-4 are placed, with a test dose of 3 mL lignocaine with adrenaline.
4. **Epidural infusion:** 0.0625 per cent bupivacaine with fentanyl 2 micrograms per mL runs at 10-12 mL/hour, with blood pressure checked every five minutes for 20 minutes and the cardiotocograph continued.
5. **Outcome:** She is pain-free, mobilising and pushing effectively at full dilatation.
6. **Contrast, second stage without anaesthesia cover:** When a lift-out forceps is anticipated, bilateral pudendal block with 1 per cent lignocaine plus perineal infiltration precedes episiotomy, with lignocaine toxicity respected at about 3 mg/kg without adrenaline, roughly 200 mg total.

In severe pre-eclampsia, epidural analgesia is favourable because it blunts pain-driven pressure surges, provided platelets exceed 80 x 10^9/L.

## Where the exam sets its traps

The screening exam tests these numbers and discriminations.

- **Trap:** Choosing pethidine for a woman who will deliver within hours — **Correct:** Neonatal effect peaks 2-3 hours after injection, so timing relative to delivery matters.
- **Trap:** Picking a neuraxial block in thrombocytopenia — **Correct:** Platelets under about 80 x 10^9/L contraindicate regional block.
- **Trap:** Overriding a woman's refusal of analgesia — **Correct:** Refusal of analgesia must be respected.
- **Trap:** Using paracervical block as a standard option — **Correct:** It causes fetal bradycardia and is now rarely used.

## Frequently asked questions

### What is the drug of choice for severe labour pain?

Epidural analgesia with low-concentration bupivacaine (0.0625-0.125 per cent) plus fentanyl 2 micrograms per mL is the drug of choice for severe labour pain. It gives the most effective relief with minimal neonatal effect.

### What is the dose of pethidine in labour and its antidote?

Pethidine in labour is given as 50-100 mg intramuscularly every 4-6 hours with an antiemetic. Neonatal respiratory depression from pethidine is reversed with naloxone 0.01 mg/kg intramuscularly or intravenously.

### How is epidural-induced hypotension managed?

Epidural-induced hypotension is managed with left uterine displacement or tilt and intravenous crystalloid. Vasopressor boluses such as ephedrine 6 mg or phenylephrine 50-100 micrograms are added, with oxygen if the mother or fetus is compromised.

### When should pethidine be avoided in labour?

Pethidine should be avoided within two to four hours of anticipated delivery. Its neonatal effect peaks 2-3 hours after the intramuscular dose and outlasts it.

### What is a pudendal block and when is it used?

A pudendal block is a bilateral injection of 10 mL of 1 per cent lignocaine below the ischial spines, blocking S2-S4. It is used for second-stage analgesia, instrumental delivery and episiotomy repair where neuraxial techniques are unavailable.