# Cover Test and Hirschberg Test

> Cover test and Hirschberg test for MBBS Ophthalmology, covering tropia and phoria detection, corneal reflex grading, and the Krimsky and Maddox rod methods.

- Canonical URL: https://prepelephant.com/topics/mbbs/ophthalmology/cover-test-and-hirschberg-test
- Exam / course: MBBS · Subject: Ophthalmology
- Publisher: PrepElephant (https://prepelephant.com) — Prepared and reviewed by the PrepElephant Academic Review Team
- First published: 2026-10-14
- Last updated: 2026-10-14
- Reference basis: Kanski's Clinical Ophthalmology; Comprehensive Ophthalmology
- How to cite: "Cover Test and Hirschberg Test", PrepElephant, https://prepelephant.com/topics/mbbs/ophthalmology/cover-test-and-hirschberg-test

## Direct answer

The cover test is a bedside method that separates a manifest squint (tropia) from a latent one (phoria) by covering and uncovering each eye. The Hirschberg test estimates the size of a squint from the position of the corneal light reflex, with roughly seven degrees of deviation for each millimetre of decentration. Krimsky and Maddox rod methods measure the deviation more precisely when the cover test alone is not enough.

## What you must remember

- **Cover-uncover test:** a refixation movement when the cover is removed indicates a tropia, while no movement indicates a phoria controlled by fusion.
- **Alternate cover test:** covering each eye in turn reveals the total deviation, including the latent component.
- **Hirschberg test:** the corneal reflex sits nasally in exotropia and temporally in esotropia, with about seven degrees per millimetre of decentration.
- **Krimsky test:** prisms placed before the fixing eye until the corneal reflex in the deviating eye is centred, with the prism strength giving the deviation.
- **Maddox rod:** a red glass rod turns a point of light into a streak, and the streak's position against the light measures the phoria or tropia.
- **Distance and near:** both must be measured, because accommodative and intermittent squints often differ between the two.
- **Phoria versus tropia:** a phoria is a latent deviation held in check by fusion, whereas a tropia is a manifest misalignment that is always present or intermittent.

## Choosing the right test and reading the result

Each test answers a different question, and the usual order is the cover-uncover test first, followed by measurement. The table summarises what each method is used for.

| Test | What it measures | Best used for |
|---|---|---|
| Cover-uncover | Tropia versus phoria at distance and near | Confirming a manifest squint |
| Alternate cover | Total deviation, including latent components | Quantifying the whole squint |
| Hirschberg | Approximate angle from the corneal reflex | Quick estimate in young or uncooperative patients |
| Krimsky and Maddox rod | Angle using prisms or a red rod | Measuring when the cover test is unreliable |

The Hirschberg method is quick but approximate, so it is used for an estimate rather than a final measurement. Its main value is in young children, where the cover test is hard to perform reliably.

A reflex that is clearly nasal or temporal is still worth recording, even when the exact angle cannot be measured. The reflex should be read with the child fixating a small distant light, and the same conditions should be used at each follow-up visit so that results can be compared.

## Where the exam tries to catch you

Examiners test whether you can read the reflex in the correct direction and whether you measure at both distances.

- **Trap:** calling an eye that does not move on uncovering normal. **Correct:** no refixation movement indicates a phoria, which is a latent deviation held in check by fusion rather than the absence of one.
- **Trap:** reading the Hirschberg reflex in the wrong direction. **Correct:** a nasal reflex indicates exotropia and a temporal reflex indicates esotropia, because the deviating eye turns away from the side of the reflex.
- **Trap:** measuring only at near. **Correct:** measure at distance too, because accommodative and intermittent squints often differ between the two.

## Frequently asked questions

### What does the cover test show?

The cover test shows whether a deviation is manifest (tropia) or latent (phoria). A refixation movement when the cover is removed indicates a tropia, while no movement indicates a phoria controlled by fusion.

### What is the difference between the alternate cover and cover-uncover tests?

The cover-uncover test detects a manifest deviation, while the alternate cover test reveals the total deviation, including latent components. Both are done at distance and at near, cover-uncover first and alternate cover afterwards.

### How is the Hirschberg test interpreted?

The Hirschberg test reads the position of the corneal light reflex, with about seven degrees of deviation for each millimetre of decentration. A nasal reflex indicates exotropia, and a temporal reflex indicates esotropia.

### What does the Krimsky test measure?

The Krimsky test places prisms before the fixing eye until the corneal light reflex in the deviating eye is centred, and the prism strength gives the size of the deviation. It is useful when the cover test cannot be read reliably, as in young children.

### What is a Maddox rod used for?

A Maddox rod turns a point of light into a streak in front of one eye, and the position of the streak relative to the light measures the deviation. It is used to assess phorias and tropias at distance and at near.