# Hysteresis Loop and Retentivity

> Hysteresis loop, retentivity and coercivity for NEET-UG Physics, covering soft iron versus steel, loop area as energy loss and core material choice.

- Canonical URL: https://prepelephant.com/topics/neet-ug/physics/hysteresis-loop-and-retentivity
- Exam / course: NEET-UG · Subject: Physics
- Publisher: PrepElephant (https://prepelephant.com) — Prepared and reviewed by the PrepElephant Academic Review Team
- First published: 2026-10-14
- Last updated: 2026-10-14
- Reference basis: NCERT Physics Class 12
- How to cite: "Hysteresis Loop and Retentivity", PrepElephant, https://prepelephant.com/topics/neet-ug/physics/hysteresis-loop-and-retentivity

## Direct answer

A hysteresis loop is the closed curve traced by a ferromagnetic material's magnetisation as the applied field is cycled, showing that magnetisation lags behind the field. Retentivity is the residual magnetisation left when the field returns to zero, and coercivity is the reverse field needed to remove it. Soft iron has a narrow loop and suits transformer cores, whereas steel has a wide loop and suits permanent magnets.

## What you must remember

- **Hysteresis:** the magnetisation of a ferromagnetic specimen lags behind the applied field H, so its value at any H depends on the material's history.
- **Retentivity:** the residual flux density Br left after the field is reduced from saturation to zero; it measures how strongly the material stays magnetised.
- **Coercivity:** the reverse field Hc needed to bring the residual magnetisation to zero; it measures how hard the material is to demagnetise.
- **Loop area:** the energy dissipated as heat per unit volume in one complete cycle equals the area enclosed by the B-H loop.
- **Soft iron:** narrow loop with low retentivity and low coercivity; it is used in transformer cores and electromagnets, where repeated reversal must waste little energy.
- **Steel and alnico:** wide loop with high retentivity and coercivity; they keep their magnetism and are used for permanent magnets.

## Tracing the loop, step by step

Start with an unmagnetised specimen and follow the field through one complete cycle. Each stage fixes a point on the curve that examiners ask about most often.

1. **Magnetise to saturation:** increase H from zero, and B rises along the initial curve until a further increase in H produces no further increase in B.
2. **Reduce the field to zero:** H falls back to zero, but B does not; it stays at Br, the retentivity.
3. **Reverse the field:** apply H in the opposite direction, and B falls to zero at H = -Hc, the coercivity.
4. **Drive to negative saturation:** keep increasing the reverse field until the specimen is saturated in the opposite sense.
5. **Complete the cycle:** bring H back through zero to positive saturation, closing the path; the enclosed area gives the energy lost per cycle.

Because the loop is traced in one fixed direction, the same field H gives different values of B on the rising and falling branches. This lag is the defining feature of hysteresis, and it is why a material's magnetisation cannot be read from the field alone.

## Where the exam tries to catch you

Most trap questions swap one property of the loop for another.

- **Trap:** choosing soft iron for a permanent magnet because it magnetises quickly — **Correct:** soft iron loses its magnetism almost at once, so a permanent magnet needs high retentivity and coercivity, as in steel or alnico.
- **Trap:** treating retentivity and coercivity as the same quantity — **Correct:** retentivity is the flux density left at zero field, while coercivity is the reverse field that brings the flux density back to zero.
- **Trap:** assuming a wide loop is desirable in a transformer core because the core stays magnetised — **Correct:** the wide loop of steel wastes energy as heat every cycle, which is why transformer cores use soft iron.

## Frequently asked questions

### Which quantity is the retentivity of a magnetic material?

Retentivity is the residual flux density Br that remains in a ferromagnetic material after the magnetising field is reduced from saturation to zero. It is read directly from the point where the hysteresis loop crosses the flux density axis.

### Why is soft iron used in transformer cores?

Soft iron is used in transformer cores because its narrow hysteresis loop gives a small energy loss per magnetisation cycle, and it is easily magnetised and demagnetised. Steel would waste far more energy as heat each time the alternating current reverses the field.

### What does the area of a hysteresis loop represent?

The area of a B-H hysteresis loop represents the energy dissipated as heat per unit volume of the material in one complete cycle of magnetisation. A wider loop therefore corresponds to a larger hysteresis loss.

### Why do permanent magnets need high coercivity?

Permanent magnets need high coercivity so that opposing or stray fields cannot easily demagnetise them. A large reverse field Hc is required to bring the residual magnetisation of steel or alnico back to zero.