The slit lamp technique builds an eye examination by varying magnification, beam width and the angle between beam and microscope until each pathology reveals itself. A direct focal beam at 30-45 degrees examines the cornea and anterior chamber, and a narrow optical section localises depth within the tissue. Retroillumination, specular reflection, sclerotic scatter and cobalt-blue fluorescein are special techniques that reveal opacities, endothelium, oedema and epithelial defects respectively.

What you must remember

  • Set-up: chin in the cup, forehead on the rest and the external canthus at the headrest mark, starting at 10x to 40x.
  • Direct focal illumination: a wide parallelepiped surveys the tissue, while a narrow, sharp optical section gives depth, such as the exact layer of an infiltrate, scar or foreign body.
  • Retroillumination: light from the iris or fundus reflex silhouettes corneal and lens opacities.
  • Specular reflection: beam and microscope at equal angles off the normal light up the endothelial mosaic, where guttae and Fuchs dystrophy are seen.
  • Sclerotic scatter: a beam on the limbus travels within the cornea by total internal reflection, so oedema or faint infiltrates glow against a dark background.
  • Cobalt blue with fluorescein: epithelial defects stain green, and the Goldmann applanation tonometer reads intraocular pressure (normal 10-21 mmHg) by halving fluorescein mires.
  • Seidel test: concentrated fluorescein over a suspected leak shows flowing aqueous as a dark stream, positive for a wound leak or perforation.
  • Van Herick and red-free: Van Herick estimates peripheral anterior chamber depth from the cornea-to-iris gap at the temporal limbus, and the green red-free filter enhances vessels, haemorrhages and nerve-fibre-layer defects.

Working through an acute red eye

A 28-year-old contact lens wearer presents with a day of pain, photophobia and watering, and the examination runs in the same order every time.

  1. Diffuse, low power. Lids, lashes and the injection pattern come first, and a ciliary flush concentrated at the limbus raises the stakes immediately.
  2. Parallelepiped sweep. A wide beam sweeps the cornea from limbus to limbus, revealing a white infiltrate at 10 o'clock in the mid-periphery.
  3. Optical section. The narrow beam is approached obliquely, placing the infiltrate in the anterior stroma beneath an epithelial break. A thin beam then checks the anterior chamber, where a hypopyon would show inferiorly.
  4. Fluorescein under cobalt blue. The defect over the infiltrate stains green, and a corneal ulcer is assumed until proven otherwise, with Pseudomonas leading the differential in a contact lens wearer.
  5. Document, then check the fundus. Applanation is deferred because the cornea is suspect, and findings are drawn with clock hour, size, depth and staining pattern. A 78 D lens then confirms a quiet fundus.

Where the exam tries to catch you

Matching technique to tissue is most of the examination, so most lost marks come from naming the wrong technique.

  • Trap: answering direct focal beam for the endothelium Correct: specular reflection is the named technique, while sclerotic scatter suits faint corneal oedema and retroillumination suits lens opacities.
  • Trap: treating the beam angle as cosmetic Correct: 30-45 degrees is the working default for direct focal illumination.
  • Trap: reading applanation at the wrong endpoint Correct: the endpoint is when the inner rims of the mires just touch, and the tonometer stays in its housing on a suspected perforated eye.
  • Trap: applanating a suspected open globe Correct: never applanate or press on a suspected open globe, and use the non-contact 78 D or 90 D lenses for fundus views.

Frequently asked questions

Which illumination technique examines the corneal endothelium?

Specular reflection examines the corneal endothelium, with the beam and microscope held at equal angles off the normal. Light reflects off the endothelial mosaic, revealing guttae and pleomorphism in the cornea.

What is the purpose of the optical section?

An optical section uses a narrow, sharp beam at a wide angle to give a cross-sectional view of the cornea. It localises the lesion's depth, showing which layer an infiltrate occupies or where a foreign body sits.

What is a positive Seidel test?

A positive Seidel test shows aqueous leaking through a wound after concentrated fluorescein is applied to the surface. Under cobalt-blue light the leak dilutes the dye into a dark streaming channel, which is evidence of a leaking wound or perforation.

What is the normal intraocular pressure on applanation?

Normal intraocular pressure on applanation is approximately 10-21 mmHg, measured with a Goldmann tonometer. The reading is taken under cobalt-blue light after topical anaesthetic and fluorescein, by halving the fluorescein mires.

Why is cobalt-blue light used with fluorescein?

Fluorescein absorbs blue light and emits green, so cobalt-blue illumination makes epithelial defects, leaking wounds and applanation mires sharply visible. It is the standard light for fluorescein staining at the slit lamp.

Which lenses convert the slit lamp into a fundus biomicroscope?

Non-contact 78 D and 90 D aspheric lenses, held before the dilated pupil, convert the slit lamp into a fundus biomicroscope. They give inverted stereoscopic views of the disc and macula under slit illumination.