Radiation Units and Measurements
On this page
Direct answer
The gray is the SI unit of absorbed dose, one joule of energy absorbed per kilogram of tissue, and 1 Gy equals 100 rad. Equivalent dose in sieverts multiplies absorbed dose by a radiation weighting factor, which is 1 for X-rays, and effective dose applies tissue weighting factors to express whole-body risk. Exposure in air keeps the old unit roentgen, while radioactivity is measured in becquerel, one decay per second.
What you must remember
- Four quantities: exposure (roentgen, ionisation in air only), absorbed dose (gray, energy per kg in any material), equivalent dose (sievert, absorbed dose times wR) and effective dose (sievert, equivalent dose times wT summed over tissues).
- Conversions: 1 Gy equals 100 rad and 1 Sv equals 100 rem; gray and sievert coincide numerically for X-rays because wR equals 1.
- Radiation weighting: photons, electrons and beta particles 1; protons 2; alpha particles 20; neutrons roughly 2.5 to 21 depending on energy.
- Tissue weighting (ICRP 103): 0.12 each for bone marrow, colon, lung, stomach and breast; 0.08 for gonads; 0.04 for thyroid; 0.01 for skin and bone surface.
- Risk figure: effective dose carries a nominal risk of roughly 5 per cent per sievert for low-dose stochastic effects.
- Typical doses: PA chest about 0.02 mSv, skull 0.1 mSv, lumbar spine 1-2 mSv, abdomen 1-1.4 mSv, CT head about 2 mSv, CT abdomen and pelvis 8-10 mSv.
- Background: natural background averages about 2.4 mSv per year globally, and India's monazite-sand belt in coastal Kerala delivers several times this.
- Activity: becquerel counts one decay per second, and the curie still appears, with 1 Ci equal to 3.7 × 10¹⁰ Bq.
From roentgen to millisievert: a chest film converted
Converting one PA chest examination through each quantity shows where the distinctions matter.
- Measure exposure. An ionisation chamber near the patient measures exposure in roentgen, which counts ionisation in air only and involves no tissue.
- Convert to absorbed dose. Air's known ionisation energy converts exposure to air kerma in grays, which approximates the absorbed dose to chest tissue, with soft tissue absorbing slightly more than air.
- Apply radiation weighting. Photons carry wR equal to 1, so the equivalent dose in sieverts equals the absorbed dose in grays numerically.
- Apply tissue weighting. Each organ dose is multiplied by its wT and summed; the lung, breast and red marrow carry 0.12 each, and much of the beam dose falls on tissue of low weighting.
- Compare with background. The summed effective dose is near 0.02 mSv, roughly three days of natural background, or one four-hundredth of an average CT abdomen.
Where students lose easy marks
Three unit slips account for most errors, and a fourth confuses activity with dose.
- Trap: using exposure for tissue dose. Correct: roentgen, or C/kg, exists only in air and only for photons, so tissue dose is expressed as absorbed dose in gray.
- Trap: treating the sievert as a unit only for alpha and neutron work. Correct: every X-ray dose limit is quoted in sievert, with wR silently equal to 1.
- Trap: failing the old-unit arithmetic. Correct: 1 rad equals 1 cGy equals 10 mGy, and 1 rem equals 1 cSv equals 10 mSv, so a 500 mrad skin dose equals 5 mGy, or 5 mSv for X-rays.
- Trap: mixing up activity and dose. Correct: the becquerel counts decays, and one curie is about the activity of one gram of radium, or 3.7 × 10¹⁰ decays per second.
Frequently asked questions
What is the difference between gray and sievert?
The gray measures energy absorbed per kilogram, while the sievert multiplies gray by the radiation weighting factor to express biological effect. The two are numerically equal for X-rays because wR equals 1, but alpha particles carry twenty times the weight.
How do roentgen, rad and rem relate to SI units?
Roentgen measures exposure in air only (2.58 × 10⁻⁴ C per kg), and 1 rad equals 1 cGy while 1 rem equals 1 cSv, so 100 of each old unit equals one SI unit.
What are the radiation weighting factors for common radiations?
Photons, electrons and beta particles carry a factor of 1, protons 2, alpha particles 20, and neutrons roughly 2.5 to 21 depending on their energy.
Why is effective dose lower than the equivalent dose to the irradiated organ?
Tissue weighting factors reduce each organ's contribution to a whole-body risk figure, so a lung dose of 0.17 mSv contributes only 0.12 × 0.17, about 0.02 mSv, to the effective dose.
How does a CT abdomen dose compare with a chest radiograph?
A CT abdomen and pelvis at 8-10 mSv is roughly 400 to 500 times the 0.02 mSv of a PA chest film, which is a standard justification comparison.