Polysomnography
On this page
Direct answer
Polysomnography is an overnight montage recording sleep stage (EEG, eye movements, chin EMG) alongside airflow, effort and oxygenation, so events are scored within the stage they disrupt. An AASM apnoea is a drop of 90% or more in thermal airflow for at least 10 seconds. The apnoea-hypopnoea index, events per hour of sleep, grades obstructive sleep apnoea as mild at 5-15, moderate at 15-30 and severe above 30.
What you must remember
- Core channels: EEG (C4-A1 and O2-A1 derivations), two electro-oculogram channels, chin EMG for atonia, anterior tibialis EMG for limb movements, ECG, oronasal thermal airflow and nasal pressure, thoracic and abdominal effort belts, pulse oximetry, position sensor and snoring microphone.
- Sleep staging: N1 is transition with alpha drop-out, N2 shows K complexes and sleep spindles, N3 is slow-wave delta sleep, and stage R shows rapid eye movements with chin atonia.
- Apnoea rule: airflow falls 90% or more for 10 seconds or longer; obstructive if effort continues, central if effort ceases, and mixed if both patterns combine.
- Hypopnoea rule (AASM 2012): nasal pressure falls 30% or more for 10 seconds or longer with a 4% desaturation or an arousal; the 30% threshold counts more events than the older 50% criterion.
- Severity bands: AHI below 5 is normal, 5-15 mild, 15-30 moderate and above 30 severe; the respiratory disturbance index adds RERAs.
- Study types: type 1 attended in-laboratory PSG is the standard; type 2 is an unattended full montage; type 3 is home sleep apnoea testing with cardiorespiratory channels; type 4 uses single-channel devices.
- Split-night protocol: the diagnostic first half is followed by CPAP titration in the second half if moderate-severe OSA is demonstrated.
- Beyond OSA: MSLT diagnoses narcolepsy with mean sleep latency of 8 minutes or less and two or more sleep-onset REM periods; REM-related hypoventilation raises obesity hypoventilation, which needs CO2 measurement.
How the scoring signals split events
Scoring turns on which sensor shows the drop, with the thermal sensor carrying apnoeas and nasal pressure carrying hypopnoeas. The belts then decide the type of apnoea, and the table sets out the criteria side by side so the rules can be compared at a glance.
| Event | Signal criterion | Feature on effort belts |
|---|---|---|
| Obstructive apnoea | Airflow falls 90% or more for 10 s | Effort continues |
| Central apnoea | Airflow falls 90% or more for 10 s | Effort ceases |
| Mixed apnoea | Airflow falls 90% or more for 10 s | Both patterns in one event |
| Hypopnoea | Nasal pressure falls 30% or more for 10 s | 4% desaturation or arousal |
Obstructive and central apnoeas look identical on the flow trace, so only the effort belts can separate them during scoring. CPAP is the treatment for the obstructive type rather than the central type, which is why the effort signal decides the therapy and must appear in the report.
Where students slip
The scoring-rule confusion is the exam's favourite, and the thermal sensor scores apnoeas while nasal pressure scores hypopnoeas. Candidates also quote outdated rules, and older criteria date the answer. Severity is often spoken without its bands or computed against recording time instead of sleep time, which matters because AHI is per hour of sleep.
- Trap: quoting the older hypopnoea criteria Correct: use the AASM 2012 rule of a 30% drop for 10 seconds with a 4% desaturation or arousal, since older criteria date the answer.
- Trap: separating apnoeas by flow alone Correct: obstructive and central apnoeas look identical on flow, so only the thoracic and abdominal effort belts separate them.
- Trap: computing AHI against recording time Correct: AHI is events per hour of sleep, so poor sleep lowers the denominator and changes the figure.
Frequently asked questions
What defines an apnoea on polysomnography?
A fall of 90% or more in thermal airflow lasting at least 10 seconds. The event is obstructive or central depending on whether effort continues on the abdominal and thoracic belts during the drop.
What is the AASM 2012 hypopnoea rule?
A drop of 30% or more in nasal pressure signal for at least 10 seconds, accompanied by a 4% oxygen desaturation or an EEG arousal. The 30% threshold is lower than the older 50% criterion, so the rule counts more events.
How is obstructive sleep apnoea severity graded?
By the apnoea-hypopnoea index per hour of sleep: 5-15 is mild, 15-30 moderate and above 30 severe, while below 5 is normal. Severity is always expressed per hour of sleep, not per hour in bed.
Which patients suit home sleep apnoea testing rather than in-laboratory PSG?
Patients with a high pre-test probability of uncomplicated OSA and no significant comorbidity suit home testing. Heart failure, neuromuscular disease, opioid use or suspected hypoventilation need full PSG with CO2 measurement.
What is a split-night study?
A split-night study is a diagnostic polysomnogram in which the first half demonstrates moderate-severe OSA. CPAP titration then follows in the second half of the same night.