IOPA Technique
On this page
Direct answer
The intraoral periapical radiograph (IOPA) is made by one of two geometric techniques. The paralleling technique places the film parallel to the tooth's long axis with a perpendicular central ray, and it is the more accurate default. The bisecting angle technique, based on Cieszynski's principle of similar triangles, is reserved for shallow palates, gaggers and other difficult anatomy.
What you must remember
- Paralleling technique: the film lies parallel to the long axis of the tooth and the central ray is perpendicular to both. A 16-inch (41 cm) source-to-film distance with a beam-aiming device (Rinn-type holder) gives minimal distortion.
- Bisecting angle technique: the film rests against the crown and the central ray is directed perpendicular to the plane bisecting the angle between film and tooth. Finger-holding is used.
- Vertical angulation: too great an angle foreshortens the image, and too small an angle elongates it, a standard viva pairing.
- Horizontal angulation and alignment: incorrect horizontal angulation causes overlapping contact points, and tube-to-film misalignment causes cone cuts.
- SLOB rule (Same Lingual, Opposite Buccal): shift the tube mesially and the buccal object's image moves distally while the lingual object moves with the tube. This localises roots, canines and canal orifices.
- Film sizes: size 0 for small children, size 1 for adult anteriors, size 2 for adult posteriors and size 4 for occlusal projections.
- Exposure settings: typically 60–70 kVp and 8–10 mA on a conventional dental unit, with the identification dot always towards the incisal or occlusal edge.
- Packet orientation: the dot side identifies the tube-facing (convex) side of the film packet and prevents back-to-front mounting errors.
Getting the perfect periapical in five steps
Take a periapical of the lower left first molar with the paralleling technique.
- Set up the sensor: a size 2 sensor sits in the holder, seated in the lingual sulcus so it covers the tooth plus at least 3 mm of periapical bone, with the dot towards the occlusal surface.
- Seat the bite block: the patient closes gently onto the bite block, centring the film without bending it, since bending distorts the image.
- Align the tube: align the tube to the external indicator ring in all three planes, which delivers the perpendicular central ray automatically.
- Expose: make the exposure at appropriate settings for the unit.
- Review: check the image against a checklist before dismissing the patient.
A cone cut means tube-film misalignment. Elongated roots with blurred furcation mean the vertical angle was too shallow or the film bent, while foreshortened, squat teeth mean it was too steep.
Overlapping contacts mean the horizontal ray missed the interproximal contacts, and a cut-off apex means the film sat too occlusally or too far from the tooth. In the maxillary molar region, the zygomatic shadow and a shallow palate make life hard, so tilt the film slightly into modified paralleling or fall back on the bisecting technique. Recording which technique was used matters, because measurements differ between them.
The bisecting technique survives on anatomy: a flat palate or large torus makes true parallel placement impossible without unacceptable bending. In a gagging patient, a promptly positioned, less ideal film that yields a diagnostic image beats a perfect placement never exposed.
How the exam frames it
Two questions dominate, and both reward the reason as well as the rule.
- Trap: saying paralleling is better because it is easier to place. Correct: a parallel film-object pair with a perpendicular ray and longer focal distance gives minimal magnification and no shape distortion, whereas bisecting assumes the angle can be accurately bisected.
- Trap: applying the SLOB rule to the wrong structure. Correct: on the second film, with the tube shifted mesially, the structure whose image moves with the tube shift is lingual, and the one moving opposite is buccal.
- Trap: choosing the bisecting technique for convenience. Correct: reserve it for shallow palates, large tori and gagging patients, where parallel placement is impossible without bending.
Frequently asked questions
Which periapical technique gives the most accurate image, and why?
The paralleling technique is the most accurate, because the film parallels the tooth's long axis and the central ray strikes both perpendicularly over a longer source-to-film distance, minimising magnification and shape distortion.
What causes elongation and foreshortening in the bisecting technique?
An excessively steep vertical angle foreshortens the tooth image, while an excessively shallow (flat) vertical angle elongates it, because the ray no longer strikes the true bisector.
How does the SLOB rule localise an object?
With two films and a known tube shift, the image of a lingual object moves in the same direction as the tubehead shift, while a buccal object moves in the opposite direction. This is the meaning of Same Lingual, Opposite Buccal.
How is a gagging patient managed during periapical radiography?
Use a smaller film, placed after the patient exhales, and have the patient breathe through the nose with a fixed point of focus. Seat the film quickly in the palate or sulcus, not the tongue base, and expose immediately.