Hand Instruments in Periodontics

On this page
  1. Direct answer
  2. What you must remember
  3. Selecting curettes for a quadrant
  4. Naming traps in the instrument viva
  5. Frequently asked questions
  6. Related topics

Direct answer

Periodontal hand instruments are precision cutting tools that slice calculus and contaminated cementum off root surfaces, and each has a handle, shank, blade and cutting edge. Sickle scalers remove supragingival calculus, while curettes with rounded backs and semicircular tips are the subgingival workhorses. Universal curettes have a 90-degree blade usable on any surface, whereas Gracey curettes are area-specific, with an offset blade of about 70 degrees and one working edge per design.

What you must remember

  • Instrument parts: handle, shank and working end, with balanced instruments keeping the blade centred over the handle's long axis to prevent rotation.
  • Sickle scalers (U15 and variants): triangular cross-section and pointed tip for supragingival calculus only, since the tip lacerates pocket walls subgingivally.
  • Universal curette: blade at 90 degrees to the lower shank with two cutting edges per blade, working on all surfaces of all teeth.
  • Gracey numbering: 1-2 and 3-4 for anterior teeth, 5-6 for anterior and premolars, 7-8 and 9-10 for posterior facial and lingual surfaces, 11-12 for mesial and 13-14 for distal surfaces of posterior teeth.
  • Blade geometry: working angulation for calculus removal is 70-80 degrees between blade face and tooth, and exploration and scaling strokes stay below that.
  • Grasp and fulcrum: a modified pen grasp with an intraoral finger rest as close to the working site as possible, and an extraoral fulcrum only for maxillary posterior approaches.
  • Sharpening: a stone dressed to a 70-75 degree cutting edge angle, because a dull curette burnishes calculus into the root instead of lifting it.

Selecting curettes for a quadrant

Instrument a mandibular right posterior quadrant the way a university clinic expects. Choose the instrument by surface first, because the Gracey number tells you which face the blade serves.

  1. Scale supragingival ledges. Use the sickle scaler on buccal and lingual aspects, keeping the pointed tip coronal to the gingival margin.
  2. Move subgingival by surface. Use Gracey 13-14 for distal surfaces, 11-12 for mesial surfaces with the lower shank low against the tooth, and 7-8 or 9-10 for buccal and lingual root surfaces.
  3. Set the stroke. Establish the finger rest nearby, insert the closed blade to the base with light pressure, then open it to about 70-80 degrees.
  4. Draw the working stroke. Pull coronally in overlapping vertical or oblique channels, finishing with horizontal strokes at line angles.
  5. Plane and verify. Use root planing strokes until the surface is glass-smooth, verify with the 11/12 explorer and record which surfaces remain rough.
  6. Sharpen first. Sharpen before the session rather than after complaints, since two minutes of stone discipline preserves the edge and your wrist.

Naming traps in the instrument viva

Examiners hold up an instrument and expect its name, use and one design feature within ten seconds.

  • Trap: calling every curette a Gracey Correct: check the blade angle, 90 degrees for universal and about 70 for Gracey, plus the number of working edges and the surface-specific numbering.
  • Trap: using a sickle scaler subgingivally Correct: the pointed back and tip tear the junctional epithelium, and the triangular profile jams in curved roots.
  • Trap: hesitating on the mesial and distal Gracey pair Correct: 11-12 for mesial surfaces and 13-14 for distal surfaces of posterior teeth.

Frequently asked questions

How does a Gracey curette differ from a universal curette?

A Gracey has an offset blade of about 70 degrees with one working cutting edge, and it is area-specific by number. A universal curette has a 90-degree blade with two cutting edges and works on any tooth surface.

Which Gracey curettes are used on mesial and distal surfaces of posterior teeth?

Gracey 11-12 is used for mesial surfaces and Gracey 13-14 for distal surfaces. Their extended, offset shanks reach around line angles that straighter designs cannot.

Why are sickle scalers avoided subgingivally?

The pointed tip and triangular section lacerate the pocket lining and jam on curved roots. Sickle scalers are designed for supragingival calculus, so the rounded curette takes over below the margin.

What angulation is used for a calculus-removal working stroke?

The blade face is opened to about 70-80 degrees against the tooth. It is inserted closed to the base of the deposit, so the cutting edge bites under and lifts the calculus in a lateral-pressure stroke.

How are hand instruments sharpened?

Curettes are sharpened on a stone at the factory edge angle of about 70-75 degrees. The blade is rotated frequently so that it cuts rather than burnishes deposits.

Same topic for other exams

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for Hand Instruments in Periodontics and BDS Periodontics. Free to start.

Get the free app WhatsApp