Audiometry
On this page
Direct answer
Audiometry separates conductive from sensorineural loss by comparing air and bone conduction thresholds, then grades severity from normal (0–25 dB) to profound. Speech discrimination, particularly disproportionately poor scores or rollover, flags retrocochlear disease, while tympanometry (Jerger types A, As, Ad, B and C) probes middle-ear mechanics. Otoacoustic emissions and auditory brainstem response give objective thresholds when a patient cannot cooperate.
What you must remember
- Test range: pure tone audiometry tests 250–8000 Hz by air conduction and 250–4000 Hz by bone conduction.
- Symbols: right ear red circle and left ear blue cross for air conduction; red and blue brackets for bone conduction, right and left respectively.
- Hearing levels: normal 0–25 dB, mild 26–40, moderate 41–55, moderately severe 56–70, severe 71–90, and profound beyond 90 dB.
- Air–bone gap: above about 10 dB means conductive loss from wax, perforation, effusion or otosclerosis; air and bone lines together mean sensorineural loss; a gap with a depressed bone line means mixed loss.
- Speech reception threshold: should agree with the 500–2000 Hz pure tone average within about 6–10 dB; disagreement suggests functional hearing loss or test error.
- Tympanometry (Jerger): type A is normal; As means low compliance from otosclerosis or ossicular fixation; Ad means high compliance from ossicular discontinuity; B is flat from effusion or perforation; C shows negative pressure from Eustachian tube dysfunction.
- Acoustic reflex: absent in conductive loss; in cochlear loss it is usually present at lower levels when recruitment exists; reflex decay is a retrocochlear sign.
- Objective tests: otoacoustic emissions test outer hair cell function and serve newborn screening; auditory brainstem response (BERA) gives a threshold and detects retrocochlear delay.
Reading an audiogram, step by step
Take a worked right ear with air conduction around 45 dB across frequencies and bone conduction at 10 dB. The question is what kind of loss this is and what sits behind it.
- Find the bone line: if bone conduction sits within the normal band, whatever the air line does, the inner ear is innocent.
- Measure the gap: a 35 dB air–bone gap is a conductive loss, and tympanometry then arbitrates the cause; type As with an absent reflex argues otosclerosis, while type B with a history of otalgia argues effusion.
- Read the shape: a bilateral 4 kHz notch answers noise exposure, a rising low-frequency curve answers early Meniere disease, and a high-frequency slope answers presbycusis.
- Add speech testing: the speech reception threshold matching the 500–2000 Hz average confirms consistency, then the discrimination score is checked. A patient whose scores are only 40 per cent on phonetically balanced words, or fall as loudness rises (rollover), has a retrocochlear pattern and needs gadolinium MRI of the internal auditory meatus.
- Use objective tests when needed: in infants, the bedridden or medico-legal cases, otoacoustic emissions screen cochlear function and BERA estimates threshold and interpeak latencies electrophysiologically.
Where the exam tries to catch you
Symbol conventions and tympanogram types cost the most marks.
- Trap: treating audiogram symbols as optional trivia. Correct: right red circle, left blue cross and bracket symbols are needed to read every printed audiogram.
- Trap: naming a type B tympanogram as otosclerosis. Correct: type B is the flat trace of effusion, while otosclerosis is type As with an absent stapedial reflex.
- Trap: separating the two conductive causes by pure tones alone. Correct: tympanometry and reflexes distinguish a stiff chain from a disrupted chain.
- Trap: accepting a claimed hearing loss without checking speech reception agreement. Correct: the speech reception threshold should match the pure tone average, which is a standard test of exaggeration.
Frequently asked questions
What do air conduction and bone conduction curves each represent?
Air conduction tests the entire pathway from canal to cortex, while bone conduction bypasses the outer and middle ear. A gap of more than about 10 dB between the two curves defines conductive hearing loss.
What does a type As tympanogram indicate?
A type As tympanogram shows a shallow compliance peak from a stiff ossicular chain, classically otosclerosis. It contrasts with type Ad hypercompliance of ossicular discontinuity and the flat type B trace of middle-ear effusion.
What is rollover in speech audiometry?
Rollover is a fall in speech discrimination scores as presentation level rises. It is a retrocochlear sign seen with vestibular schwannoma and other auditory nerve lesions.
Which tests screen newborn hearing?
Otoacoustic emissions screen newborn hearing by testing outer hair cell function. Babies who fail are followed by auditory brainstem response, the two-tier protocol that assigns risk and threshold objectively.
How can audiometry help detect functional hearing loss?
A speech reception threshold that disagrees with the pure tone average by more than about 10 dB suggests functional hearing loss or test error. Present otoacoustic emissions or a normal auditory brainstem response against a claimed profound threshold also expose non-organic loss.