Primary Angle Closure Glaucoma
On this page
Direct answer
Primary angle closure glaucoma is raised intraocular pressure caused by the peripheral iris pressing against the trabecular meshwork, usually because of pupillary block in a shallow anterior chamber. It is more common in hypermetropic eyes, in women and in people of Asian ancestry. Definitive treatment is laser peripheral iridotomy, which removes the block and is performed in both eyes.
What you must remember
- Mechanism: pupillary block stops aqueous flowing from the posterior chamber through the pupil, so the peripheral iris bows forward and closes the angle.
- Risk factors: hypermetropia, female sex, older age and Asian ancestry, with a shallow anterior chamber on examination.
- Screening: Van Herick grading of 1 or 2 suggests a narrow angle that needs formal gonioscopy.
- Acute attack: pain, headache, vomiting, haloes, a red eye, a steamy cornea and a mid-dilated oval pupil, with pressure often above 40 mmHg.
- Provocative tests: the dark room test and the prone test unmask an occludable angle in an eye that looks open.
- Definitive treatment: laser peripheral iridotomy, performed in both eyes because the fellow eye has similar anatomy.
- Drugs to avoid: mydriatics and anticholinergics such as atropine, tropicamide and phenylephrine, which can precipitate an attack.
From pupillary block to a laser opening
Aqueous humour is produced in the posterior chamber and must pass through the pupil to reach the outflow tract, so the sequence below shows how a block forms and how a laser breaks it.
- Block the pupil: when the pupil sits in mid-dilation, the iris touches the lens, and aqueous cannot flow forward through the pupil.
- Bow the peripheral iris: pressure builds behind the iris, which is pushed forward and seals the angle against the trabecular meshwork.
- Raise the pressure: outflow is blocked, so intraocular pressure rises quickly and can cause severe pain and visual loss.
- Damage the tissues: the iris sphincter becomes ischaemic, the cornea swells and the optic nerve is at risk from high pressure.
- Open the angle: a laser hole in the peripheral iris lets aqueous bypass the pupil, which equalises the pressure across the iris.
- Treat the fellow eye: the other eye usually has a narrow angle too, so it is treated at the same time to prevent a later attack.
Where the exam tries to catch you
Angle-closure questions test sequence, drug choice and the need to examine the angle first.
- Trap: dilating a patient with narrow angles to look at the fundus Correct: mydriatic drops can precipitate closure, so the angle is assessed before dilation.
- Trap: giving atropine or an antihistamine to a patient with narrow angles Correct: anticholinergic drugs dilate the pupil and can trigger an acute attack.
- Trap: treating only the eye with the attack and leaving the fellow eye alone Correct: the fellow eye has similar anatomy, so laser iridotomy is performed in both eyes.
Frequently asked questions
What is the mechanism of primary angle closure glaucoma?
Primary angle closure glaucoma results from pupillary block, in which aqueous cannot pass from the posterior chamber through the pupil. The peripheral iris is pushed forward and closes the trabecular angle. Intraocular pressure rises because outflow is blocked.
Which drugs should be avoided in primary angle closure glaucoma?
Mydriatic and anticholinergic drugs such as atropine, tropicamide and phenylephrine should be avoided in primary angle closure glaucoma. They dilate the pupil and can precipitate an acute attack. Some antihistamines and tricyclic antidepressants are also cautioned against.
What is the definitive treatment for primary angle closure glaucoma?
Laser peripheral iridotomy is the definitive treatment for primary angle closure glaucoma, creating an opening in the peripheral iris to bypass the pupillary block. It is performed in both eyes, because the fellow eye is usually at similar risk. The procedure is done once the acute attack is controlled.
Which provocative tests unmask angle closure?
The dark room test and the prone test are provocative tests used to unmask an occludable angle. The pupil dilates in darkness, or pressure rises when the patient lies prone, and either change indicates a narrow angle. These tests are used in eyes that look open on initial examination.