Experimental Physics for JEE

On this page
  1. Direct answer
  2. What you must remember
  3. Reading a screw gauge, step by step
  4. Where the marks are lost
  5. Frequently asked questions
  6. Related topics

Direct answer

Experimental physics for JEE turns instrument readings into marks, and every reading starts with the least count and the zero error. A vernier caliper's least count is 1 MSD minus 1 VSD, typically 0.1 mm, while a screw gauge's is its pitch divided by its circular divisions, typically 0.01 mm. The corrected reading equals the observed reading minus the zero error, sign included.

What you must remember

  • Vernier caliper: LC = 1 MSD − 1 VSD; reading = main-scale reading plus coincident vernier division × LC, with outside jaws for thickness and the tail strip for depth.
  • Screw gauge: LC = pitch divided by the number of circular divisions; reading = pitch-scale reading plus coincident circular division × LC.
  • Standard least counts: vernier caliper 0.1 mm (0.02 mm on a 50-division vernier), screw gauge 0.01 mm, metre scale 1 mm, stopwatch 0.1 s.
  • Sign discipline: a closed-jaw reading of +0.04 mm is a zero error that comes off every reading, while a closed reading of 98 divisions on a 100-division gauge means −0.02 mm, which adds.
  • Linearisation pairs: T² versus l for a pendulum (slope 4π²/g), v versus t for uniform acceleration, 1/v versus 1/u for a lens, V versus I for Ohm's law.
  • Graph hygiene: scales should cover more than half the graph paper, the best-fit line is drawn rather than joining dots, and the slope comes from two widely separated points on that line.
  • Practical habits: rotate a screw gauge in one direction only, measure a wire's diameter in two perpendicular directions and average, and average several timing trials.

Reading a screw gauge, step by step

A wire sits between the stud and spindle of a screw gauge with 0.5 mm pitch and 50 circular divisions, and the closed-jaw reading is +0.04 mm. The steps turn the scale readings into a corrected diameter, using the same logic for any instrument.

  1. Read the pitch scale. The sleeve has passed the 0.5 mm mark, so the main reading is 0.5 mm.
  2. Read the circular scale. The 27th circular division sits on the reference line, adding 27 × 0.01 mm = 0.27 mm to give an observed diameter of 0.77 mm.
  3. Apply the zero error. The corrected diameter is 0.77 − 0.04 = 0.73 mm, with the sign of the zero error included.
  4. Rotate through 90 degrees. Measure again in the perpendicular direction, because drawn wire is rarely perfectly round and one diameter alone can mislead.
  5. Average the two. The accepted diameter is the mean of the two corrected readings.

Where the marks are lost

The exam options usually differ by a sign or a single division, so arithmetic precision earns the marks.

  • Trap: adding the zero error when it should be subtracted, because the closed-jaw reading is treated as a correction. Correct: the corrected reading equals observed minus zero error with its sign, so a corrected zero must give zero.
  • Trap: taking one main-scale division as the least count of a vernier. Correct: LC = 1 MSD − 1 VSD, so ten vernier divisions spanning nine main divisions give 0.1 mm.
  • Trap: plotting T against l and reading g from a curve. Correct: plot T² against l, where the slope 4π²/g gives g, and a non-zero intercept exposes a fixed error.
  • Trap: reversing the screw gauge while fine-tuning the reading. Correct: turn in one direction only, because reversing lets play in the worn thread appear as backlash error.

Frequently asked questions

What is the least count of a standard vernier caliper?

The standard vernier caliper has a least count of 0.1 mm, because ten vernier divisions coincide with nine main-scale divisions. So one vernier division is 0.9 mm and the least count is 1 − 0.9 = 0.1 mm, while a 50-division vernier achieves 0.02 mm.

How is zero error applied to a measurement?

The corrected reading equals the observed reading minus the zero error, with its sign. A gauge that already reads +0.04 mm with closed jaws has that amount removed from every subsequent reading of the experiment.

Why plot T squared against l instead of T against l?

Because T = 2π√(l/g) gives a curve, whereas T² = (4π²/g) l is a straight line through the origin. Its slope 4π²/g delivers g cleanly and averages out random timing error across the data points.

Which instrument suits a wire's diameter versus a tube's internal diameter?

A screw gauge with 0.01 mm least count suits the wire, while the internal jaws of a vernier caliper suit the tube. A screw gauge cannot reach inside a bore, so the vernier's internal jaws are the right tool there.

Why must a screw gauge be rotated in one direction only?

Reversing the rotation lets play in the worn screw thread appear as a false reading, called backlash error. All final adjustments should therefore be made turning the same way.

Same topic for other exams

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for Experimental Physics for JEE and JEE Physics. Free to start.

Get the free app WhatsApp