Hysterosalpingography Anatomy

On this page
  1. Direct answer
  2. What you must remember
  3. Reading the pattern on a single film
  4. Where the exam tries to catch you
  5. Frequently asked questions
  6. Related topics

Direct answer

Hysterosalpingography outlines the uterine cavity and fallopian tubes by injecting water-soluble contrast through the cervix under fluoroscopy. A normal uterine cavity is triangular, and normal tubes fill through a narrow isthmus into a wider ampulla, then spill contrast freely into the pelvis. A septate uterus produces a midline filling defect, while a tubal blockage stops contrast from passing beyond the obstruction.

What you must remember

  • Normal uterine cavity: an inverted triangle with smooth walls and the cornua at its upper corners, continuous below with the endocervical canal.
  • Isthmus: the narrow medial part of the tube, where proximal obstruction most often occurs.
  • Ampulla: the wider lateral segment of the tube, the usual site of fertilisation.
  • Free spill: contrast leaking from the fimbrial ends into the pelvis confirms that the tube is patent on that side.
  • Septate uterus: a midline septum gives a filling defect dividing the cavity, with a flat or minimally indented fundus.
  • Bicornuate uterus: an indentation of the fundus gives a heart-shaped cavity, a pattern usually distinct from the septate uterus, although MRI or 3D ultrasound is needed to separate them reliably.
  • Timing: the study is done in the early proliferative phase after menstruation, to exclude pregnancy and keep the endometrium thin.

Reading the pattern on a single film

Hysterosalpingography is interpreted by pattern rather than by any single measurement. Each finding has a typical appearance and a clear meaning, and the interpretation depends on where the contrast goes rather than on the outline of the uterus alone.

Finding Appearance on HSG What it means
Normal uterus Triangular cavity, smooth walls No structural abnormality
Septate uterus Midline filling defect, flat fundus Fused septum dividing the cavity
Bicornuate uterus Heart-shaped cavity, fundal indentation Two horns fused at the base
Proximal tubal block Contrast stops at the isthmus, no spill Cornual or isthmic obstruction
Distal tubal block Tube fills and dilates, no spill Hydrosalpinx from fimbrial or ampullary blockage
Patent tube Contrast spills from the fimbriae Tubal patency confirmed

A bilateral patent tube is the key favourable result in an infertility work-up. Proximal and distal blocks can look alike on one film, so a delayed image or a laparoscopic check may be needed to separate them. A poorly distended cavity can also hide a small polyp or septum, so the cavity should be seen to fill fully before the tubes are judged.

Where the exam tries to catch you

Viva questions on hysterosalpingography focus on confusing uterine anomalies and on the meaning of missing spill.

  • Trap: reading a septate uterus as a bicornuate one. Correct: a septum gives a midline defect with a flat fundus, whereas a bicornuate uterus gives a fundal indentation with a heart-shaped cavity.
  • Trap: calling a tube blocked because no spill appears on a single view. Correct: a delayed film may show spill, so the absence of spill alone does not prove an obstruction.
  • Trap: performing the study at any point in the cycle. Correct: it is done soon after menstruation, since pregnancy must be excluded and the endometrium should be thin for a clear view.

Frequently asked questions

When is hysterosalpingography performed in the menstrual cycle?

Hysterosalpingography is performed in the early proliferative phase, soon after menstruation ends and before ovulation. This timing reduces the risk of exposing an early pregnancy to radiation and keeps the endometrium thin enough for a clear view.

What does a septate uterus look like on hysterosalpingography?

A septate uterus shows a midline filling defect dividing the uterine cavity, with a flat or minimally indented fundus. This pattern separates it from a bicornuate uterus, which shows an indentation at the fundus and a heart-shaped cavity.

How is a proximal tubal block distinguished from a distal block?

In a proximal block contrast stops at the isthmus and does not enter the tube, whereas in a distal block the tube fills and dilates into a hydrosalpinx without spilling. Both show no spill on a single film, so a delayed image or laparoscopy may be needed.

What does free peritoneal spill on hysterosalpingography indicate?

Free spill of contrast from the fimbrial ends into the pelvis indicates that the fallopian tube is patent on that side. Bilateral spill is the key favourable result in an infertility work-up.

What is the normal shape of the uterine cavity on hysterosalpingography?

The normal uterine cavity appears as an inverted triangle, with smooth walls and the cornua at its upper corners. Any departure from this outline, such as a midline defect or fundal indentation, points to a uterine anomaly.

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for Hysterosalpingography Anatomy and MBBS Anatomy. Free to start.

Get the free app WhatsApp