Complement Fixation Test

On this page
  1. Direct answer
  2. What you must remember
  3. Working through the two-stage reaction
  4. Where the exam tries to catch you
  5. Frequently asked questions
  6. Related topics

Direct answer

The complement fixation test detects antigen or antibody by measuring whether complement has been consumed in an antigen-antibody reaction. In the first stage, antigen, serum antibody and a fixed dose of complement are incubated, and complement is fixed only if the specific pair has reacted. The second stage adds sheep red cells with anti-sheep antibody, and haemolysis shows that complement remained free, which means a negative result.

What you must remember

  • Two stages: Stage one fixes complement when specific antigen and antibody react, and stage two uses sensitised sheep red cells as an indicator of how much complement is left.
  • Haemolytic indicator system: Sheep red cells plus rabbit anti-sheep antibody, called the amboceptor, lyse only when free complement is available.
  • Negative result: Complete haemolysis in the tube means complement was not fixed, so no specific reaction occurred.
  • Positive result: No haemolysis means complement was consumed, showing that the antigen and antibody reacted.
  • Heat inactivation: Patient serum is heated to 56 degrees Celsius for about 30 minutes to destroy native complement before testing.
  • Historical use: The Wassermann reaction for syphilis was a complement fixation test that detected reagin, with later versions using a cardiolipin-based antigen.
  • Present uses: Complement fixation is still used in reference laboratories for some infections, including Q fever caused by Coxiella burnetii.
  • Limitations: It needs standardised reagents and fresh complement, and ELISA or immunofluorescence has largely replaced it.

Working through the two-stage reaction

The test is easy to misread because a positive reaction produces no visible change in the first stage. The sequence below shows how the indicator system reveals the result.

  1. Inactivation: Patient serum is heated at 56 degrees Celsius to destroy its own complement, so only the added complement takes part.
  2. Stage one set-up: Antigen, the inactivated serum and a fixed, pre-titrated dose of complement are mixed and incubated.
  3. Fixation: If the specific antigen and antibody have reacted, complement binds to the immune complex and is used up.
  4. Indicator addition: Sheep red cells sensitised with amboceptor are added to the tube.
  5. Stage two incubation: Sensitised cells bind any remaining complement, and they lyse only if free complement is present.
  6. Read-out: Complete haemolysis indicates a negative test, while no haemolysis indicates fixation and a positive test.
  7. Controls: Antigen, serum, complement and haemolytic system controls are run alongside the test to confirm that each reagent works.

Where the exam tries to catch you

Most lost marks come from reversing haemolysis and fixation, or from forgetting why serum is heated.

  • Trap: Reading haemolysis as a positive reaction. Correct: Haemolysis means free complement remained, so the test is negative, while the absence of haemolysis means fixation and a positive result.
  • Trap: Forgetting to heat inactivate the patient serum. Correct: Native complement in unheated serum would be consumed or would lyse indicator cells, giving false results.
  • Trap: Treating complement fixation as the current first-line test. Correct: ELISA and immunofluorescence have replaced it for most infections, though some reference laboratories still use it.
  • Trap: Calling anticomplementary serum a true positive. Correct: Some sera activate or consume complement nonspecifically, so anticomplementary controls are essential before interpreting results.

Frequently asked questions

Why is patient serum heated to 56 degrees Celsius before a complement fixation test?

Heating patient serum to 56 degrees Celsius for about 30 minutes inactivates its native complement in the complement fixation test. This ensures that only the complement added in the test takes part in the reaction. Without inactivation, the patient's own complement would produce false results.

What does haemolysis mean in the second stage of the complement fixation test?

Haemolysis in the second stage means complement remained free after the first stage, so the antigen and antibody did not react. The complement fixation test is negative in this case. The absence of haemolysis means complement was fixed, which is a positive result.

Why was the Wassermann test important in syphilis serology?

The Wassermann test was a complement fixation test that, in later versions, used a cardiolipin-based antigen to detect reagin-type antibodies in syphilis. It served as the standard screening method for decades. It has since been largely replaced by non-treponemal flocculation tests and specific treponemal assays.

Which infections are still diagnosed by complement fixation?

Complement fixation remains in use for some infections, including Q fever caused by Coxiella burnetii, and certain fungal and chlamydial infections in reference laboratories. Its use is limited because standardised reagents are hard to maintain. ELISA or immunofluorescence usually replace it in routine practice.

What is an anticomplementary serum in the complement fixation test?

An anticomplementary serum is one that activates or consumes complement without any specific antigen-antibody reaction. It causes false positive results in the complement fixation test by fixing complement nonspecifically. Serum and complement controls detect this effect before results are interpreted.

Same topic for other exams

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for Complement Fixation Test and MBBS Microbiology. Free to start.

Get the free app WhatsApp