Polymerase Chain Reaction and Its Variants
On this page
Direct answer
Polymerase chain reaction is an in vitro technique that exponentially amplifies a specific DNA segment, using two primers that flank the target and a thermostable DNA polymerase. The reaction cycles through denaturation, annealing and extension, and each cycle ideally doubles the target. Variants extend the method to RNA through reverse transcription, to quantification in real time, and to greater sensitivity or multiple targets.
What you must remember
- Taq polymerase: A thermostable enzyme from Thermus aquaticus that survives repeated denaturation, but it lacks 3' to 5' proofreading, so its error rate is higher.
- Cycle steps: Denaturation near 94 to 95 °C, primer-specific annealing, and extension at 72 °C, usually repeated 25 to 40 times.
- Exponential amplification: Ideal yield is 2 to the power n after n cycles, so 30 cycles theoretically give about a billion-fold increase.
- RT-PCR: Reverse transcriptase first converts RNA into cDNA, which makes RNA viruses such as SARS-CoV-2 and HCV detectable.
- Real-time PCR: Fluorescence is read every cycle, and the cycle threshold (Ct) falls as the starting target increases; CBNAAT, used under the National TB Elimination Programme, works on this principle.
- Nested PCR: Two rounds with two primer sets, the second placed inside the first product, raise sensitivity and specificity.
- Multiplex PCR: Several primer pairs in one reaction detect multiple targets, such as several pathogens or resistance genes, in a single run.
- Contamination: Carry-over of amplicons causes false positives, so pre- and post-PCR areas are kept separate and negative controls are run.
The thermal cycle, step by step
A PCR run is a repeated three-step temperature cycle that doubles the target each time it completes. Each step has a specific job, and temperature and primer design decide whether the reaction succeeds. Understanding the steps explains both the power of the method and its plateau.
- Denaturation: Heating to about 94 to 95 °C separates the double-stranded template into single strands, making the target accessible to the primers.
- Annealing: The temperature drops to a value set by the primers, typically somewhere between 50 and 65 °C, so each primer binds its complementary sequence on the template.
- Extension: Taq polymerase works at 72 °C, adding nucleotides from the 3' end of each primer and copying the template strand for the full target length.
- Repetition: Every complete cycle doubles the number of target copies, so the product grows exponentially over 25 to 40 cycles.
- Plateau: As primers, nucleotides and enzyme run out, amplification slows and stops rising, which is why standard end-point PCR cannot quantify the starting template reliably.
Where the exam tries to catch you
Questions on PCR usually test what the method detects, which variant suits a given situation, and how errors arise.
- Trap: Assuming a positive PCR shows the organism is alive. Correct: PCR detects nucleic acid, which can persist after death or effective treatment, so viability cannot be inferred from a positive result.
- Trap: Using standard end-point PCR to measure viral load. Correct: Quantification requires real-time PCR, because end-point products reach a plateau and do not reflect the starting copy number.
- Trap: Selecting Taq polymerase where high-fidelity copying is needed. Correct: Taq lacks proofreading, so enzymes with 3' to 5' exonuclease activity, such as Pfu, are preferred when accuracy matters.
Frequently asked questions
Why is Taq polymerase used in the polymerase chain reaction?
Taq polymerase is used because it is thermostable and survives repeated denaturation at about 95 °C. It was isolated from Thermus aquaticus, a bacterium found in hot springs. Its lack of proofreading activity is a drawback where high fidelity is needed.
What is the difference between RT-PCR and real-time PCR?
RT-PCR is a method that begins with reverse transcription of RNA into cDNA, whereas real-time PCR monitors amplification as it occurs. The two can be combined, as in real-time RT-PCR used for RNA viral load testing. One term describes the template type and the other describes how amplification is measured.
What does cycle threshold mean in real-time PCR?
Cycle threshold is the cycle number at which the fluorescence signal crosses a set threshold above background. A lower Ct value indicates a higher starting quantity of target nucleic acid in the sample. Ct values are used for quantification and to estimate viral load.
When is nested PCR preferred over conventional PCR?
Nested PCR is preferred when the target is present in very low copy number or when specificity must be improved. It uses two rounds of amplification with two primer sets, the second placed inside the first product. The method carries a greater risk of carry-over contamination, so strict laboratory separation is needed.
Why must PCR laboratories separate pre- and post-amplification areas?
Pre- and post-amplification areas are separated to prevent carry-over contamination from amplified products reaching fresh reactions. Even small amounts of amplicon can produce false-positive results in polymerase chain reaction testing. Separate workflow, dedicated equipment and negative controls reduce this risk.