Carbon Monoxide Poisoning Physiology
On this page
Direct answer
Carbon monoxide poisoning is tissue hypoxia caused by carboxyhaemoglobin, because haemoglobin binds carbon monoxide roughly 200 to 250 times more avidly than oxygen. It cuts oxygen carriage and shifts the dissociation curve to the left, so arterial PO2 can stay normal while tissues are starved of oxygen. Pulse oximetry reads carboxyhaemoglobin as oxyhaemoglobin, so co-oximetry is needed to measure the true level.
What you must remember
- Affinity: haemoglobin binds carbon monoxide roughly 200 to 250 times more avidly than oxygen, forming carboxyhaemoglobin that cannot carry oxygen.
- Left shift: carbon monoxide binding to one haem increases the affinity of the remaining sites, so oxygen is held tightly and unloaded poorly.
- Normal PaO2: dissolved oxygen is unaffected, so arterial PO2 is normal even when oxygen content falls sharply.
- Pulse oximetry: cannot tell carboxyhaemoglobin from oxyhaemoglobin, so readings can look falsely normal, and co-oximetry measures the true value.
- Oxygen treatment: 100 per cent oxygen through a high-flow mask shortens the half-life of carboxyhaemoglobin to about 60 to 90 minutes, compared with several hours on room air.
- Sources in India: coal and charcoal braziers, bukhari heaters in cold regions, and gas or kerosene appliances used in closed rooms.
How the two effects combine
Carbon monoxide damages oxygen delivery through two linked changes, which is why the classic findings are misleading when read on their own.
- Carriage loss: carboxyhaemoglobin takes the place of oxyhaemoglobin, so less oxygen can be carried per unit of blood even with a normal PaO2.
- Curve shift: the left shift holds oxygen on haemoglobin, so tissue unloading falls even where some oxygen is still present.
- Dissolved oxygen: the partial pressure of dissolved oxygen is unchanged, so the arterial blood gas looks reassuring.
- Measurement error: standard pulse oximetry overestimates saturation, so the clinician may be falsely reassured.
- Tissue effect: the brain and heart are most sensitive, and carbon monoxide also binds cytochrome oxidase, which further impairs cellular oxygen use.
The table below contrasts the normal picture with carbon monoxide poisoning for the parameters a student is most often asked about.
| Parameter | Normal | Carbon monoxide poisoning |
|---|---|---|
| Arterial PO2 | Normal | Normal |
| Oxygen content | Normal | Reduced |
| Carboxyhaemoglobin | Low | Raised |
| Pulse oximetry | Accurate | Falsely normal |
| Dissociation curve | Standard | Left shifted |
The gap between a normal PO2 and a poor oxygen content is the defining feature of this hypoxia. It makes carbon monoxide poisoning an anaemic or carrying-capacity hypoxia, not a failure of the lungs to oxygenate blood.
Where the exam tries to catch you
Most errors come from trusting a normal number that the poisoning does not affect.
- Trap: concluding there is no hypoxia because the PaO2 is normal. Correct: the defect is in oxygen carriage, so the content falls even with a normal PO2.
- Trap: relying on pulse oximetry to confirm adequate oxygenation. Correct: it reads carboxyhaemoglobin as oxygen saturation, so co-oximetry is the right test.
- Trap: treating a cherry-red colour as an early sign. Correct: cherry-red skin is a late and inconsistent finding, so its absence does not exclude poisoning.
- Trap: expecting room air to clear carboxyhaemoglobin quickly. Correct: room air takes several hours, whereas 100 per cent oxygen reduces the half-life to about an hour.
Frequently asked questions
Why is arterial PO2 normal in carbon monoxide poisoning?
Arterial PO2 is normal in carbon monoxide poisoning because the gas does not change the partial pressure of dissolved oxygen. The defect lies in haemoglobin's reduced capacity to carry oxygen, so content falls while PO2 stays normal.
Why does pulse oximetry give a falsely normal reading in carbon monoxide poisoning?
Pulse oximetry gives a falsely normal reading because it measures two wavelengths and cannot distinguish carboxyhaemoglobin from oxyhaemoglobin. The device therefore reports a saturation that looks adequate even when much of the haemoglobin is carbon monoxide bound.
What is the half-life of carboxyhaemoglobin during oxygen therapy?
The half-life of carboxyhaemoglobin is about 60 to 90 minutes during treatment with 100 per cent oxygen, compared with several hours on room air. Faster clearance is one reason high-flow oxygen is the first-line treatment.
What type of hypoxia does carbon monoxide poisoning cause?
Carbon monoxide poisoning causes anaemic or carrying-capacity hypoxia, because haemoglobin is prevented from carrying oxygen. The arterial PO2 and the lungs are normal, which separates it from hypoxic hypoxia.