ECG Basics

On this page
  1. Direct answer
  2. What you must remember
  3. How to read a tracing in a fixed order
  4. Where students slip
  5. Frequently asked questions
  6. Related topics

Direct answer

The electrocardiogram, or ECG, is the graphic record of the heart's electrical activity, picked up from electrodes on the body surface. The P wave is atrial depolarisation, the QRS complex is ventricular depolarisation and the T wave is ventricular repolarisation. Each heartbeat therefore produces one coordinated sequence of waves whose shape and timing reveal rhythm, conduction and myocardial problems.

What you must remember

  • Waves and complexes: P is atrial depolarisation, QRS is ventricular depolarisation and T is ventricular repolarisation; the small U wave, when present, is attributed to Purkinje fibre or papillary muscle repolarisation.
  • Intervals: PR is 0.12 to 0.20 seconds and reflects the AV nodal delay in conduction from atria to ventricles; QRS is 0.08 to 0.10 seconds; QT varies with rate and roughly corresponds to ventricular systole.
  • Paper calibration: the standard speed is 25 mm per second, so one small square is 0.04 seconds and one large square 0.2 seconds; a 10 mm deflection equals 1 mV.
  • Leads: bipolar limb leads I, II and III form Einthoven's triangle, in which lead II equals the sum of leads I and III; augmented leads are aVR, aVL and aVF; six precordial leads, V1 to V6, lie over the chest.
  • Heart rate: divide 300 by the number of large squares between successive R waves, or 1500 by the number of small squares.
  • Axis: a positive R in lead I with a negative deflection in aVF suggests left axis deviation, and the reverse pattern suggests right axis deviation.
  • Abnormalities: P mitrale and P pulmonale indicate atrial enlargement, while Q waves, ST changes and T inversion suggest infarction or ischaemia.

How to read a tracing in a fixed order

A tracing is read in a fixed sequence so that nothing is missed. Each step checks one feature before the next is interpreted.

  1. Calibrate: confirm the paper speed of 25 mm per second and the 10 mm equals 1 mV standardisation before measuring anything.
  2. Rate and regularity: divide 300 by the large squares between R waves, or 1500 by the small squares, and check whether the R-R intervals are regular.
  3. Rhythm and PR: confirm that each QRS follows a P wave, and check that the PR interval falls between 0.12 and 0.20 seconds.
  4. Conduction: measure the QRS duration, and look for a short PR with a slurred upstroke, which suggests an accessory pathway as in Wolff-Parkinson-White syndrome.
  5. Axis: use leads I and aVF, where a positive lead I with a negative aVF indicates left axis deviation and the reverse indicates right axis deviation.
  6. Morphology: inspect for P mitrale, P pulmonale, Q waves, ST changes and T inversion, which point to atrial enlargement, infarction or ischaemia.

Where students slip

Most errors come from confusing what the tracing records with what it does not.

  • Trap: equating the ECG with mechanical events. Correct: it records electrical activity only, so it cannot measure contractility, and a normal ECG does not guarantee normal pumping.
  • Trap: looking for a separate atrial T wave. Correct: atrial repolarisation is hidden within the QRS, and the ventricular T wave is what ends ventricular systole electrically.
  • Trap: confusing the PR interval with the PR segment. Correct: the PR interval runs from the onset of P to the onset of QRS, while the PR segment runs from the end of P to the onset of QRS.

Frequently asked questions

What does each wave of the ECG represent?

The P wave is atrial depolarisation, the QRS complex is ventricular depolarisation and the T wave is ventricular repolarisation. Atrial repolarisation is merged within the QRS complex.

What is the normal PR interval and what does it reflect?

The normal PR interval lies between 0.12 and 0.20 seconds and measures conduction from the atria to the ventricles, chiefly the delay at the AV node. Prolongation indicates first-degree heart block.

What is Einthoven's law?

Einthoven's law states that lead II equals the algebraic sum of leads I and III, because the three bipolar limb leads form a triangle around the heart. The relationship is used to check for electrode placement errors.

How do you calculate heart rate from an ECG?

Divide 300 by the number of large squares between two consecutive R waves when the rhythm is regular. For an irregular rhythm, count the R waves in a set length of the rhythm strip instead.

Which findings suggest left or right axis deviation?

Left axis deviation shows a positive QRS in lead I with a negative deflection in lead aVF, while right axis deviation shows the reverse pattern. Lead aVR is not the deciding lead, so a negative aVR alone does not establish the axis.

What do examiners expect in the ECG practical and OSCE?

Candidates must record a rhythm strip, calculate the rate and R-R regularity, identify a normal sinus rhythm tracing and demonstrate limb and chest electrode placement. Viva questions often ask why the ECG cannot measure contractility.

Same topic for other exams

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for ECG Basics and MBBS Physiology. Free to start.

Get the free app WhatsApp