Perimetry and Visual Fields
On this page
Direct answer
Perimetry is the measurement of the visual field, the area seen by each eye while it fixates a central point, and it is recorded for each eye separately. Normal limits are roughly 60 degrees nasally, 90 to 100 degrees temporally, 50 to 60 degrees superiorly and 65 to 75 degrees inferiorly, and defects are charted against these limits to localise disease.
What you must remember
- Confrontation test: a quick bedside screen that compares the patient's field with the examiner's at about one metre; it detects only gross defects.
- Tangent screen: a black screen with a white target at a set distance, such as one metre, charts the central 30 degrees, as on the Bjerrum screen.
- Goldmann perimetry: kinetic perimetry in which a moving target is carried inwards to plot isopters.
- Automated static perimetry: a fixed target is presented at increasing brightness at set locations, and the machine records the threshold at each point.
- Blind spot: the optic disc lies about 15 degrees temporal to fixation, and an enlarged blind spot points to papilloedema or disc swelling.
- Reliability indices: fixation losses, false-positive and false-negative responses flag an unreliable test.
- Glaucoma pattern: arcuate defects and a nasal step respect the horizontal midline, reflecting the nerve fibre arrangement at the disc.
How a static field is performed and read
Automated static perimetry is the usual test in clinical practice, and its reliability depends on the steps taken before the test begins. The sequence below runs from set-up to interpretation.
- Correction and fixation: correct the refractive error and ask the patient to keep the eye on the central fixation target throughout.
- Grid choice: the 24-2 programme suits most glaucoma and neurological fields, while the 10-2 programme examines the macula in detail.
- Threshold testing: the machine flashes spots of increasing brightness at each location until the patient responds, and records the threshold there.
- Reliability review: check fixation losses and false-positive and false-negative responses before accepting the result.
- Comparison with normals: the printout compares each point with an age-matched database and shows mean deviation and pattern standard deviation.
- Pattern recognition: look for a nasal step, arcuate scotoma, hemianopia or central scotoma, and match it to the anatomy of the pathway.
A defect with a sharp vertical border respecting the vertical midline points to a chiasmal or retrochiasmal lesion, as in bitemporal or homonymous hemianopia. An arcuate defect that respects the horizontal midline points to the optic nerve head, as in glaucoma.
Where the exam tries to catch you
Perimetry questions usually test the blind spot, the test chosen and the reliability of the printout.
- Trap: reading the normal blind spot as a field defect Correct: the blind spot is physiological, so only an enlarged blind spot matters, and it points to papilloedema or optic disc disease.
- Trap: labelling a field loss that respects the horizontal midline as hemianopic Correct: glaucomatous defects respect the horizontal meridian, whereas hemianopic defects respect the vertical midline.
- Trap: accepting a single abnormal field without checking reliability Correct: high fixation losses or false-positive responses can create artefactual defects, so the test should be repeated.
- Trap: using the confrontation test to quantify glaucoma Correct: confrontation detects only gross defects, while threshold perimetry measures sensitivity and tracks progression over time.
Frequently asked questions
Where is the normal blind spot located in the visual field?
The normal blind spot lies about 15 degrees temporal to fixation, slightly below the horizontal meridian. It corresponds to the optic disc, which has no photoreceptors. An enlarged blind spot is an abnormal finding and suggests papilloedema or disc swelling.
Why do glaucomatous field defects respect the horizontal midline?
Glaucomatous damage follows the arcuate nerve fibre bundles, which are separated along the horizontal meridian at the optic disc. Field defects therefore stop at that line, producing the arcuate defect and nasal step. A hemianopic defect, by contrast, respects the vertical midline.
What does a Bjerrum screen test?
A Bjerrum screen is a tangent screen that tests the central 30 degrees of the visual field at a standard distance, commonly one metre. It is used to map central and paracentral scotomas. A Bjerrum scotoma, an arcuate defect near fixation, is a classic glaucoma finding.
Which perimetry programme is used for routine glaucoma follow-up?
The 24-2 programme on automated static perimetry is commonly used for routine glaucoma follow-up, since it samples the central 24 degrees on a standard grid. The 10-2 programme is added when the central macula needs detailed examination. The programme chosen should be stated with the report so that results can be compared over time.
What do the reliability indices in perimetry measure?
Reliability indices in perimetry measure fixation losses, false-positive responses and false-negative responses. High values suggest that the patient did not maintain fixation or responded unreliably. A field with poor reliability should be repeated before the defect is accepted as real.