SA Node Pacemaker and Automaticity
On this page
Direct answer
The sinoatrial node is the heart's normal pacemaker, generating spontaneous action potentials at about 60 to 100 per minute in a resting adult because its cells undergo slow phase 4 depolarisation. This automaticity is driven mainly by the funny current carried by HCN channels, which open on hyperpolarisation, and by calcium channels that bring the membrane to threshold.
What you must remember
- Phase 4 depolarisation: the slow diastolic rise that carries the membrane from its most negative level to threshold.
- Funny current (If): an inward current through HCN channels that open during hyperpolarisation, mainly carrying sodium into the cell.
- Calcium channels: T-type and L-type channels contribute to late phase 4 and the upstroke, which is calcium-dependent in the SA node.
- Maximum diastolic potential: about minus 60 mV in the SA node, less negative than in ventricular muscle.
- Overdrive suppression: a faster pacemaker keeps slower latent pacemakers quiet by repeatedly driving them.
- Latent pacemakers: the AV junction, at about 40 to 60 per minute, and the His-Purkinje system, at about 20 to 40 per minute, take over only if the SA node fails.
- Autonomic control: vagal acetylcholine slows the rate, while sympathetic noradrenaline speeds it.
One cycle of the pacemaker, step by step
The SA node cycle is a loop in which each action potential resets the membrane, and the pacemaker current then rebuilds the slow rise to threshold. The steps below follow one complete cycle.
- Reset: after the previous action potential the membrane reaches its most negative level, near minus 60 mV.
- Funny current: HCN channels open on hyperpolarisation, admitting sodium that slowly depolarises the cell.
- Calcium entry: T-type and then L-type calcium channels open as the potential nears threshold.
- Upstroke: calcium influx drives a slow upstroke to threshold, producing the action potential.
- Repolarisation: potassium efflux restores the resting level, and the cycle starts again.
The rate of the heart is set by how steeply phase 4 rises. A steeper slope reaches threshold sooner and gives a faster rate.
Sympathetic noradrenaline acts on beta-1 receptors to raise cAMP, which steepens phase 4 depolarisation. This is why exercise raises the heart rate and why beta blockers slow it.
Where the exam tries to catch you
Pacemaker questions often hinge on which ion carries the upstroke and what the autonomic nerves do to the slope.
- Trap: saying the SA node upstroke is sodium-driven like ventricular myocytes. Correct: the SA node upstroke is calcium-dependent, which is why it is slow and why calcium channel blockers slow the rate.
- Trap: thinking vagal stimulation speeds the heart. Correct: vagal activity opens potassium channels, hyperpolarises the node and reduces the slope of phase 4.
- Trap: confusing overdrive suppression with AV node pacing. Correct: overdrive suppression keeps latent pacemakers quiet, and the AV node rhythm appears only when SA drive fails.
Frequently asked questions
Why is the SA node the normal pacemaker of the heart?
The SA node is the normal pacemaker because its cells have the fastest intrinsic rate of spontaneous phase 4 depolarisation. Its impulses overdrive the AV node and the His-Purkinje system, so the rest of the heart follows its rhythm.
What is the funny current in the sinoatrial node?
The funny current, called If, is an inward current carried mainly by sodium through HCN channels that open during hyperpolarisation. It drives the slow phase 4 depolarisation of the SA node and is increased by sympathetic stimulation.
What rate do latent pacemakers in the AV node usually fire at?
AV junctional pacemakers usually fire at about 40 to 60 per minute, while His-Purkinje pacemakers fire more slowly, at about 20 to 40 per minute. These latent rhythms take over only when the SA node fails.
How does vagal stimulation slow the SA node?
Vagal stimulation releases acetylcholine that opens potassium channels in SA node cells, hyperpolarising them and reducing the slope of phase 4 depolarisation. Threshold is then reached more slowly, so the heart rate falls.