Ventilation-Perfusion Mismatch

On this page
  1. Direct answer
  2. What you must remember
  3. Two patients at the extremes
  4. How the exam frames it
  5. Frequently asked questions
  6. Related topics

Direct answer

Ventilation-perfusion (V/Q) mismatch is the departure of local V/Q from the overall normal ratio of 0.8, set by 4 L/min ventilation and 5 L/min perfusion. Gravity makes matching imperfect even in health, so the upright apex runs a V/Q near 3 and the base about 0.6. Shunt, where V/Q is zero, and dead space, where it is infinite, are the extremes that cause hypoxaemia and wasted ventilation.

What you must remember

  • Ratio and derivation: 4 L/min alveolar ventilation divided by 5 L/min pulmonary perfusion gives 0.8; quote both numbers, since examiners ask for them.
  • Apex-base physiology: ventilation and perfusion both fall from base to apex, but perfusion falls faster, so the apex runs a V/Q of about 3 and the base about 0.6.
  • Apical tuberculosis: high alveolar PO2 near 130 mmHg favours the aerobic tubercle bacillus, and low perfusion limits immune delivery, an Indian exam staple.
  • Shunt (V/Q = 0): perfused but unventilated blood, seen in pneumonia, atelectasis, ARDS and right-to-left cardiac shunts; hypoxaemia does not correct with 100 per cent oxygen.
  • Dead space (V/Q infinite): ventilated but unperfused alveoli, with pulmonary embolism the prototype; anatomical dead space is 150 mL, and physiological dead space is about 30 per cent of tidal volume at rest, rising in disease (Bohr equation).
  • Physiological shunt: 2-5 per cent of cardiac output normally, from thebesian and bronchial venous drainage.
  • A-a gradient: normal 5-15 mmHg and rising with age (roughly age divided by 4, plus 4); hypoventilation keeps it normal, while every other mechanism raises it.
  • Hypoxaemia mechanisms: hypoventilation, diffusion impairment, V/Q mismatch and shunt, with V/Q mismatch the commonest cause of arterial hypoxaemia in clinical medicine.

Two patients at the extremes

Two patients show the extremes, and their response to 100 per cent oxygen separates them.

  1. Start with the blood gas: A young woman on oral contraceptives with acute pleuritic breathlessness has PaO2 60 mmHg, PaCO2 32 mmHg and a widened A-a gradient, which points to a matching problem rather than simple hypoventilation.
  2. Identify the embolus: The clot has cut perfusion to ventilated alveoli, creating dead space, and hyperventilation explains her low PaCO2.
  3. Expect a modest fall: Dead space does not itself desaturate blood, so PaO2 falls only modestly, with the rest of the drop coming from flow redirected into low V/Q units.
  4. Contrast consolidation: A man with lobar pneumonia has perfused but unventilated lung, which is a true shunt, and his PaO2 barely rises on 100 per cent oxygen.
  5. Apply the oxygen test: The embolism patient corrects toward normal on 100 per cent oxygen, whereas shunted blood through consolidated alveoli cannot be oxygenated.

In COPD, exercise drops mixed venous oxygen content, because working muscle extracts more oxygen. That darker blood cycles through poorly ventilated units and emerges on the steep part of the dissociation curve, where a small PO2 change costs a large saturation drop.

How the exam frames it

Three ideas recur in examiners' questions on this subject.

  • Trap: Assuming shunt and dead space both respond to oxygen in the same way. Correct: Shunt is the only hypoxaemia mechanism not corrected by 100 per cent oxygen, while dead space wastes ventilation without initially desaturating blood.
  • Trap: Assuming the apex is better perfused because it is higher. Correct: The apex is the worst perfused region of the upright lung, with V/Q near 3 against about 0.6 at the base.
  • Trap: Forgetting the body's own V/Q correction. Correct: Hypoxic pulmonary vasoconstriction (Euler-Liljestrand) diverts blood from poorly ventilated alveoli; when generalised, as at altitude or in COPD, it causes pulmonary hypertension and eventually cor pulmonale.

Frequently asked questions

What is the normal ventilation-perfusion ratio, and how is it derived?

The normal overall ventilation-perfusion ratio is about 0.8, derived by dividing alveolar ventilation of 4 L/min by pulmonary blood flow of 5 L/min. It describes average matching across the whole lung.

Why does the lung apex have a higher V/Q ratio than the base?

Gravity reduces both ventilation and perfusion toward the apex, but perfusion falls more steeply. The apex is therefore relatively overventilated, with a V/Q of about 3, while the base is overperfused, with a V/Q of about 0.6.

Which cause of hypoxaemia is not corrected by 100 per cent oxygen?

Right-to-left shunt, with a V/Q of zero, is not corrected by 100 per cent oxygen. Shunted blood bypasses ventilated alveoli entirely and continues to dilute arterial oxygen content.

What is the normal A-a gradient, and when does it stay normal?

The normal alveolar-arterial oxygen gradient is 5 to 15 mmHg in a young adult. It stays normal in pure hypoventilation and when inspired PO2 is low, as at high altitude, and it widens with diffusion impairment, V/Q mismatch and shunt.

Why does reactivated pulmonary tuberculosis favour the lung apex?

The apex has the highest alveolar PO2, around 130 mmHg, which favours the aerobic tubercle bacillus. Low blood flow and lymphatic stasis there also limit immune clearance, which together favour reactivation.

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for Ventilation-Perfusion Mismatch and MBBS Physiology. Free to start.

Get the free app WhatsApp