Amniocentesis and Invasive Prenatal Testing
On this page
Direct answer
Amniocentesis is ultrasound-guided aspiration of amniotic fluid at 15 to 16 weeks, giving fetal cells for karyotype or microarray in women aged 35 and over, after abnormal screening, or for structural anomalies. Its procedure-related loss is about 0.5 per cent or less. Chorionic villus sampling at 10 to 13 weeks gains earliness at about 1 to 2 per cent loss, while third-trimester amniocentesis assesses lung maturity.
What you must remember
- Amniocentesis numbers: 15 to 16 weeks (15 to 20 acceptable); 20 to 22G needle under continuous ultrasound; discard the first 1 to 2 mL to avoid maternal contamination; anti-D 300 micrograms for Rh-negative women.
- Indications: age 35 or older at delivery, high-risk screen or NIPT, previous aneuploidy, structural anomaly, parental translocation or X-linked conditions.
- CVS specifics: 10 to 13 weeks, transcervical or transabdominal; loss 1 to 2 per cent; before 10 weeks it carries transverse limb-reduction defects, and 1 to 2 per cent placental mosaicism may need amniocentesis confirmation.
- Rapid tests versus culture: QF-PCR or FISH for chromosomes 13, 18, 21, X and Y reports in 24 to 48 hours; culture karyotype takes 10 to 14 days; microarray adds copy-number changes.
- Third-trimester lung maturity: a lecithin-sphingomyelin ratio of 2 or more indicates maturity (about 3.5 in diabetic pregnancy), with phosphatidylglycerol adding assurance; the Indian bedside classic is the foam test.
- Cordocentesis: umbilical vein sampling from 18 weeks for rapid karyotype, fetal anaemia assessment (middle cerebral artery Doppler first) and intrauterine transfusion in rhesus isoimmunisation.
- Legal frame: the PCPNDT Act (1994, amended 2003) requires registration of facilities and machines, written consent and an absolute prohibition on disclosing fetal sex.
One procedure from counselling to report
A 37-year-old at 16 weeks has a quad screen risk of 1 in 80 for trisomy 21 and opts for amniocentesis. Each stage of the procedure carries its own safety or reporting step, and each is documented.
- Counsel and consent: explain the 0.5 per cent loss risk, bleeding, leak and infection, and obtain written consent on the prescribed form before any needle is touched.
- Position under ultrasound: choose a pocket away from the placenta and fetal face, infiltrate the skin and advance the needle in one thrust.
- Discard and collect: the first 2 mL are discarded, then 18 mL is withdrawn into a dry syringe.
- Protect and send her home: Rh-negative women receive anti-D, and she rests briefly before reporting bleeding, leaking, fever or pain over 48 hours.
- Report in stages: QF-PCR within two days, culture confirmation in two weeks, and microarray when the indication was a structural anomaly.
Where the exam tries to catch you
Viva and MCQ traps cluster around timing, consent and legal duties.
- Trap: reaching for CVS before 10 weeks. Correct: transverse limb-reduction defects make early CVS unsafe, so the 10 to 13 week window applies.
- Trap: disclosing fetal sex to a family with an X-linked condition. Correct: counsel about the disease, not the sex, since the PCPNDT Act makes disclosure a punishable offence.
- Trap: treating an L/S ratio of 2 as certain. Correct: it signals lung maturity, phosphatidylglycerol adds certainty, and the threshold is about 3.5 in diabetic pregnancy.
Frequently asked questions
At what gestation and volume is diagnostic amniocentesis performed?
Diagnostic amniocentesis is performed at 15 to 16 weeks, with 15 to 20 weeks acceptable. About 1 mL of fluid per gestational week is aspirated, typically 15 to 20 mL, through a 20 to 22G needle under ultrasound guidance.
What advantages and risks distinguish CVS from amniocentesis?
CVS at 10 to 13 weeks gives results about a month earlier than amniocentesis but carries a slightly higher loss rate of 1 to 2 per cent. It also brings a risk of limb-reduction defects before 10 weeks and placental mosaicism that may need confirmatory amniocentesis.
What does an L/S ratio of 2 signify?
An L/S ratio of 2 means lecithin exceeds sphingomyelin two-fold, indicating fetal lung maturity. The ratio of about 3.5 is the prudent threshold in diabetic pregnancy, and phosphatidylglycerol adds certainty.
When is cordocentesis chosen over amniocentesis?
Cordocentesis from 18 weeks is chosen for rapid karyotype in urgent situations, fetal haemoglobin assessment, and treatment such as intrauterine transfusion in rhesus isoimmunisation. It samples umbilical vein blood directly, which is why it serves treatment as well as diagnosis.
What does the PCPNDT Act require of a doctor performing amniocentesis?
The PCPNDT Act requires registration of the facility and equipment, a documented indication with written consent on the prescribed form, and meticulous records. It also absolutely prohibits disclosing fetal sex.