Fundus Fluorescein Angiography Interpretation

On this page
  1. Direct answer
  2. What you must remember
  3. Reading the dye study by phase
  4. Where the exam tries to catch you
  5. Frequently asked questions
  6. Related topics

Direct answer

Fundus fluorescein angiography is an intravenous dye study that shows retinal and choroidal circulation by photographing sodium fluorescein as it passes through the eye. Interpretation rests on timing, with early frames showing filling and late frames showing leakage, and on whether an area is hyper- or hypofluorescent. Hyperfluorescence can mean leakage or a window defect, and hypofluorescence can mean blockage or non-perfusion, so late frames are checked first.

What you must remember

  • Dye: 10 per cent sodium fluorescein is injected intravenously and absorbs blue light at about 490 nm, emitting green-yellow light at about 520 nm.
  • Arm-retina time: the interval to first retinal arterial filling is normally about 10 to 15 seconds, and a prolonged value suggests slow flow.
  • Window defect: hyperfluorescence from loss of retinal pigment epithelium, visible from the early frames and constant in the late frames.
  • True leakage: hyperfluorescence that grows over the late frames, as in classic choroidal neovascularisation and cystoid oedema.
  • Blocked fluorescence: hypofluorescence from blood, haemorrhage, xanthophyll or pigment that hides the choroidal background.
  • Filling defect: hypofluorescence from real non-perfusion, as in diabetic capillary dropout or retinal vascular occlusion.
  • ICG angiography: indocyanine green fluoresces in the near-infrared, so it shows the deeper choroid better than fluorescein.

Reading the dye study by phase

A 60-year-old woman with a sudden fall in vision has leakage on her angiogram. Read the study by phase, first the timing and then the pattern, so that the diagnosis rests on evidence rather than on the first bright spot.

  1. Note the arm-retina time. Record when dye first appears in the retinal arteries, normally about 10 to 15 seconds, since prolongation suggests slow circulation such as in carotid disease or retinal artery occlusion.
  2. Assess the arterial and arteriovenous phases. Look for laminar flow, transit through the capillaries and any area of non-perfusion, which appears as hypofluorescence.
  3. Examine the venous phase. Veins fill fully with dye, and dye staining of the vessel walls may suggest periphlebitis or retinal vasculitis.
  4. Classify the abnormal fluorescence. Decide whether each spot is hyperfluorescent from leakage, window or staining, or hypofluorescent from blockage or a filling defect.
  5. Check the late frames. Leakage that grows with time indicates true leakage, a window defect stays constant, and staining stays confined to the tissue that holds it.
  6. Match the pattern to the diagnosis. A well-defined bright lesion with late leakage suggests classic choroidal neovascularisation, and a petaloid pattern suggests cystoid macular oedema.
  7. Note the safety points. Warn of transient nausea and yellow skin or urine, and have resuscitation equipment available for rare anaphylaxis.

Where the exam tries to catch you

Most errors come from calling a constant window defect a leak, and from mistaking blocked fluorescence for ischaemia.

  • Trap: calling a window defect leakage Correct: a window defect is visible from the early frames and stays constant, whereas true leakage grows over time.
  • Trap: attributing hypofluorescence in a haemorrhage to non-perfusion Correct: blocked fluorescence from blood or pigment hides the background, whereas a filling defect shows absent dye in a region of real ischaemia.
  • Trap: reading smokestack leakage as classic neovascularisation Correct: smokestack leakage is typical of central serous chorioretinopathy, while classic neovascularisation shows a well-defined bright lesion.

Frequently asked questions

What is arm-retina time in fluorescein angiography?

Arm-retina time is the interval from dye injection to its first appearance in the retinal arteries, normally about 10 to 15 seconds. A prolonged value suggests slow circulation, as seen in carotid disease or a retinal artery occlusion.

What is a window defect on fluorescein angiography?

A window defect is hyperfluorescence caused by loss of retinal pigment epithelium, which lets the choroidal fluorescence show through. It is seen from the early frames and does not grow in the late frames, which distinguishes it from true leakage.

What is the smokestack pattern in central serous chorioretinopathy?

Smokestack leakage is a plume of dye from a retinal pigment epithelium defect into the subretinal space, widening over time. It is a characteristic finding in central serous chorioretinopathy and helps distinguish it from classic choroidal neovascularisation.

What late pattern suggests cystoid macular oedema on angiography?

Cystoid macular oedema shows petaloid or flower-petal leakage in the late frames, as dye accumulates in the cystic spaces around the fovea. This pattern is classic in pseudophakic cystoid macular oedema, also called Irvine-Gass syndrome.

When is indocyanine green angiography preferred over fluorescein?

Indocyanine green angiography is preferred when the deeper choroid must be seen, because its near-infrared fluorescence passes through the pigment and blood more easily. It is used for polypoidal choroidal vasculopathy and choroidal lesions that fluorescein cannot show clearly.

Same topic for other exams

Practise this in the PrepElephant app

Question banks, previous-year questions, mock tests and revision tools — for Fundus Fluorescein Angiography Interpretation and NEET-PG Ophthalmology. Free to start.