Macular Hole and Epiretinal Membrane
On this page
Direct answer
A macular hole is a full-thickness defect of the fovea, usually idiopathic and most often seen in women in the sixth and seventh decades. Vitreofoveal traction is the driving force, and Gass staging on biomicroscopy and OCT guides the timing of treatment. Pars plana vitrectomy with internal limiting membrane peeling and gas tamponade closes most holes that are operated on.
What you must remember
- Gass stage 1: an impending or occult hole with a yellow spot and loss of the foveal depression, without vitreous separation, often observed.
- Gass stage 2: a small full-thickness hole, below about 400 microns, with the vitreous still attached.
- Gass stage 3: a larger full-thickness hole with the posterior hyaloid separated from the fovea but still attached to the optic disc.
- Gass stage 4: a hole with complete posterior vitreous detachment, marked on fundoscopy by a Weiss ring.
- Epiretinal membrane: a cellophane-like membrane causing wrinkling and distortion, called macular pucker, without a full-thickness break.
- OCT: the key investigation, showing whether a defect is full thickness and separating a true hole from a pseudohole or lamellar hole.
- Surgery: pars plana vitrectomy, internal limiting membrane peeling and an intraocular gas or silicone tamponade, with positioning after surgery.
Reasoning from a central blur to a closed hole
A 68-year-old woman notices central blur and a distorted grid in one eye. The examiner must stage the lesion, decide whether surgery is needed and separate a hole from an epiretinal membrane.
- Confirm on OCT: spectral-domain OCT shows whether the defect is full thickness, and it separates a true hole from a pseudohole or a lamellar hole.
- Stage by Gass: the biomicroscopic stage and the OCT appearance of the hole guide the decision, and a full-thickness hole usually prompts surgery.
- Check the fellow eye: the other eye is examined because a hole can develop there, and the vision and the symptoms are recorded before treatment.
- Operate with vitrectomy: pars plana vitrectomy removes the vitreous traction, and internal limiting membrane peeling provides a scaffold for closure of the hole.
- Tamponade and position: an intraocular gas bubble such as SF6 or C3F8 holds the edges together, and the patient keeps the head positioned as advised, usually face down for a period.
- Avoid nitrous oxide: while any gas remains in the eye, nitrous oxide anaesthesia is avoided because it expands the bubble and can raise intraocular pressure sharply.
- Assess the result: OCT at postoperative visits confirms closure, and the final vision depends on the size and duration of the hole.
Where the exam tries to catch you
Macular questions often hinge on a single OCT feature or a single drug interaction.
- Trap: operating every epiretinal membrane Correct: a membrane is observed unless metamorphopsia or reduced vision is significant, because surgery is not urgent.
- Trap: confusing a macular pseudohole with a true hole Correct: a pseudohole shows an inward-pulled foveal edge with intact tissue on OCT, so it is managed differently from a full-thickness break.
- Trap: giving nitrous oxide after an intraocular gas injection Correct: nitrous oxide diffuses into the bubble and expands it, which is why it is avoided until the gas has resorbed.
Frequently asked questions
What are the Gass stages of macular hole?
Gass staging grades a macular hole from stage 1, an impending hole with a yellow spot and no vitreous separation, through stage 2, a small full-thickness hole with vitreous attached. Stage 3 is a larger hole with partial vitreous detachment, and stage 4 is a hole with complete posterior vitreous detachment.
Which surgery closes a full-thickness macular hole?
Pars plana vitrectomy with internal limiting membrane peeling and gas tamponade is the standard surgery for a full-thickness macular hole. The gas bubble holds the retina in place while the fovea heals, and the patient is positioned as advised for a few days after surgery.
Why must nitrous oxide be avoided after intraocular gas?
Nitrous oxide diffuses into an intraocular gas bubble and expands it, which can raise intraocular pressure sharply and damage the optic nerve or retina. Anaesthetists therefore avoid nitrous oxide while any gas bubble remains in the eye.
How does an epiretinal membrane differ from a macular hole?
An epiretinal membrane is a cellophane-like membrane on the macular surface that wrinkles the retina without a full-thickness defect. A macular hole is a true break in the fovea, and OCT is the investigation that separates the two and guides management.
What is a macular pseudohole?
A macular pseudohole is a foveal depression caused by an epiretinal membrane pulling the edges inwards, without a full-thickness break. OCT shows the retinal tissue intact at the fovea, so the condition is managed differently from a true macular hole.